MODEL: PCLP50
PCLP100
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting.Follow the heating equipment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association (NFPA),and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within
walls or ceilings or into attics,crawl spaces, or garages.
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control
Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dust brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-
ses, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
Use an on/off switch to operate this fan. See "Connect Wiring" for details.
PLAN THE INSTALLATION
1. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
PCLP80
VENTILATION FAN
INSULATION*
(Place around and
over Fan Housing.)
FAN
POWER
HOUSING
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
Seal duct
*
Purchase
joints with
tape.
separately
1
ROOF CAP*
(with built-in
damper)
Keep duct
runs short
WALL CAP*
(with built-in
ROUND
damper)
ELBOW(S) *

Advertisement

loading

Summary of Contents for S&P PCLP50

  • Page 1 VENTILATION FAN MODEL: PCLP50 PCLP80 PCLP100 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Page 2 ASSEMBLY INSTRUCTIONS 1. Before installation, you need to know: ST4.2*13mm Screw A Channel B Distance A Screw B ST4.2*25mm Hanger bar 7 1/2 in (190mm) Hole B Hole B (short) Hole A Hole A Hanger bar 13 3/8 in (340mm) (long) JOIST Channel A...
  • Page 3 Run 120V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown. For model: PCLP50 , PCLP80 and PCLP100 BLACK (BLK)
  • Page 4 OPTION FUNCTION If need to add option function (humitidy sensor, speed controller ect.), put relevant power box in the place showed right, fixed it with screws, and insert the plug from the box into the suitable wire panel. Screw Connect electrical wiring refer to “CONNECT ELECTRICAL WIRING” . INSTALL GRILLE Install ceiling material to complete the ceiling construction.

This manual is also suitable for:

Pclp80Pclp100