S&P PC50XP Quick Start Manual
S&P PC50XP Quick Start Manual

S&P PC50XP Quick Start Manual

Ventilation fan

Advertisement

Quick Links

Models: PC50XP

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refriger-
ation and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual
noises, replace the motor with the exact service motor. The impeller should also be replaced.

OPERATION

See "CONNECT ELECTRICAL WIRING" for details.
Installer: Leave this manual with the homeowner.
READ AND SAVE THESE INSTRUCTIONS
VENTILATION FAN
Cod: 0060302628-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PC50XP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S&P PC50XP

  • Page 1 VENTILATION FAN Models: PC50XP WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Page 2 PLAN THE INSTALLATION 1. Do not install fan above or inside a 45-degree angle projected outwards from the cooking equipment element closest to the fan. See instruction sheet for clarification. 2. Two ways to connect ductwork to a factory-shipped unit. INSULATION* ROOF CAP* (Place around and...
  • Page 3 ASSEMBLY INSTRUCTIONS 4. Install DUCT AND BLOWER ASSEMBLY Hole a. Install duct from the inside of the housing; Fix the duct by the tab. b. Fix the BLOWER ASSEMBLY to the housing by 3 screws. Hole Hole 5. INSTALL ROUND DUCTWORK a.
  • Page 4 INSTALL GRILLE Install ceiling material to complete the ceiling construction and cut around the fan housing. To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly towards the ceiling to secure.

Table of Contents