6
York PREDATOR DM 150 manuals available for free PDF download: Installation Manual, Technical Manual, Installation Instruction
York PREDATOR DM 150 Installation Manual (60 pages)
Predator SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS 7-1/2, 10 AND 12-1/2 TON (9.0 TO 10.0 EER) 50 Hz
Brand:
York
| Category:
Air Conditioner
| Size: 2.66 MB
Table of Contents
Table of Contents
2
General
5
Safety Considerations
5
Inspection
5
Reference
6
Renewal Parts
6
Approvals
6
Nomenclature
7
Installation
8
Installation Safety Information
8
Preceding Installation
8
Unit Shipping Bracket
8
Condenser Covering
8
Compressor Section
8
Limitations
9
Location
10
Rigging and Handling
10
Unit 4 Point Load
10
Unit Voltage Limitations
10
Unit Temperature Limitations
10
Clearances
11
Unit 6 Point Load
11
Unit Center of Gravity
11
Unit Weight
11
Point Load Weight
11
Unit Dimensions
12
Unit Height
12
Unit Clearances
12
Bottom Duct Openings (from Above)
13
Rear Duct Dimensions
13
Ductwork
14
Duct Covers
14
Roof Curbs
14
Condensate Drain
15
Compressors
15
Filters
15
Side Panels with Hole Plugs
15
Return Downflow Plenum with Panel
15
Discharge Panel in Place
15
Thermostat Wiring
16
Power and Control Wiring
16
Power Wiring Detail
16
Control Wire Sizes
16
Electronic Thermostat Field Wiring
17
Field Wiring Disconnect - Cooling Unit with or Without Electric Heat
18
Field Wiring Disconnect - Cooling Unit
18
Electrical Data 7-1/2 Ton
19
Electrical Data 10 Ton
19
Electrical Data 12-1/2 Ton
20
Physical Data
20
Optional Electric Heat
21
Optional Gas Heat
21
Bottom Entry Gas Piping
21
Gas Piping
21
Side Entry Gas Piping
21
Electric Heat Minimum Supply Air Cfm
21
Gas Application Data
21
Gas Connection
22
Gas Pipe Sizing - Capacity of Pipe
22
Lp Units, Tanks and Piping
23
Vent and Combustion Air
23
Options/Accessories
23
Economizer
23
Electric Heat
23
Motorized Outdoor Damper
23
Power Exhaust
23
Rain Hood
23
Economizer and Power Exhaust Set Point Adjustments and Information
24
Enthalpy Set Point Adjustment
24
Indoor Air Quality Aq
24
Minimum Position Adjustment
24
Power Exhaust Damper Set Point (with or Without Power Exhaust)
24
Enthalpy Set Point Chart
25
Honeywell Economizer Control W7212
25
Phasing
26
Blower Rotation
26
Belt Tension
26
Belt Adjustment
26
Supply Air Limitations
26
Blower Performance 7-1/2 Ton Standard Motor - Side Duct (Imperial)
27
Blower Performance 7-1/2 Ton Standard Motor - Side Duct (Metric)
27
Blower Performance 7-1/2 Ton Optional Motor - Side Duct (Imperial)
27
Blower Performance 7-1/2 Ton Optional Motor - Side Duct (Metric)
27
Blower Performance 10 Ton Standard Motor - Side Duct (Imperial)
28
Blower Performance 10 Ton Standard Motor - Side Duct (Metric)
28
Blower Performance 10 Ton Optional Motor - Side Duct (Imperial)
28
Blower Performance 10 Ton Optional Motor - Side Duct (Metric)
29
Blower Performance 12-1/2 Ton - Side Duct (Imperial)
29
Blower Performance 12-1/2 Ton - Side Duct (Metric)
29
Yim-B
29
Blower Performance 7-1/2 Ton
30
Blower Performance 7-1/2 Ton Standard Motor - Downshot (Metric)
30
Blower Performance 7-1/2 Ton Optional Motor - Downshot (Imperial)
30
Blower Performance 7-1/2 Ton Optional Motor - Downshot (Metric)
31
Blower Performance 10 Ton Standard Motor - Downshot (Imperial)
31
Blower Performance 10 Ton Standard Motor - Downshot (Metric)
31
Blower Performance 10 Ton Optional Motor - Downshot (Imperial)
32
Blower Performance 10 Ton Optional Motor - Downshot (Metric)
32
Blower Performance 12-1/2 Ton - Downshot (Imperial)
33
Blower Performance 12-1/2 Ton - Downshot (Metric)
33
Indoor Blower Specifications
33
Air Balance
34
Checking Air Quantity
34
Method One
34
Method Two
34
Dry Coil Delta P 50" Cabinet
35
Dry Coil Delta P 42" Cabinet
35
Supply Air Drive Adjustment
36
Additional Static Resistance 50" Cabinet
37
Additional Static Resistance 42" Cabinet
37
Additional Static Resistance 50" Cabinet
38
Additional Static Resistance 42" Cabinet
38
Motor Sheave Datum
39
Operation
40
Sequence of Operations Overview
40
Cooling Sequence of Operation
40
Continuous Blower
40
Intermittent Blower
40
No Outdoor Air Options
40
Economizer with Single Enthalpy Sensor
40
Economizer with Dual Enthalpy Sensors
40
Economizer with Power Exhaust
41
Motorized Outdoor Air Dampers
41
Cooling Operation Errors
41
High-Pressure Limit Switch
41
Low-Pressure Limit Switch
41
Freezestat
41
Low Ambient Cooling
41
Safety Controls
41
Compressor Protection
42
Flash Codes
42
Reset
42
Electric Heating Sequence of Operations
42
Electric Heat Operation Errors
42
Temperature Limit
42
Safety Controls
42
Limit Switch (Ls)
42
Electric Heat Anticipator Setpoints
42
Electric Heat Limit Setting
42
Gas Heating Sequence of Operations
43
Ignition Control Board
43
First Stage of Heating
43
Recycle Operation
43
Retry Operation
43
Second Stage of Heating
43
Gas Heating Operation Errors
43
Flame Sense
43
Lock-Out
43
Temperature Limit
43
Auxiliary Limit Switch (Als)
44
Flash Codes
44
Internal Microprocessor Failure
44
Limit Switch (Ls)
44
Pressure Switch (Ps)
44
Resets
44
Rollout Switch (Ros)
44
Safety Controls
44
Gas Heat Anticipator Setpoints
44
Typical Flame
44
Start-Up (Cooling)
45
Prestart Check List
45
Operating Instructions
45
Post Start Check List
45
Start-Up (Gas Heat)
45
Lighting the Main Burners
45
Shut down
45
Manifold Gas Pressure Adjustment
46
Checking Gas Input
46
Natural Gas
46
Gas Heat Stages
46
Adjustment of Temperature Rise
47
Burners/Orifices Inspection/Servicing
47
Gas Rate Cubic Feet Per Hour
47
Charging the Unit
48
Typical Gas Valve
48
Ton Superheat Charging
48
Ton Superheat Charging
49
Troubleshooting
50
Predator® Flash Codes
50
Unit Control Board Flash Codes
50
Yim-B
50
Ignition Control Flash Codes
51
Unit Control Board
51
Basic Troubleshooting Flowchart
52
Power on Flow Chart
52
Trip Failure Flow Chart
53
Cooling Troubleshooting Guide
54
Gas Heat Troubleshooting Guide
57
Advertisement
York PREDATOR DM 150 Installation Manual (44 pages)
SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE ELECTRIC UNITS 7-1/2 TO 12-1/2 TON (380V, 3 Phase, 60 HZ)
Brand:
York
| Category:
Air Conditioner
| Size: 1.78 MB
Table of Contents
Table of Contents
2
General
5
Safety Considerations
5
Inspection
5
Reference
5
Approvals
5
Nomenclature
6
Installation
10
Installation Safety Information
10
Preceding Installation
10
Limitations
10
Unit Shipping Bracket
10
Condenser Covering
10
Compressor Section
10
Location
11
Rigging and Handling
11
Predator ® Component Location
11
Unit Voltage Limitations
11
Unit Temperature Limitations
11
Clearances
12
Unit 4 Point Load
12
Unit 6 Point Load
12
Unit Center of Gravity
12
Unit Weights
12
Point Load Weight
12
Unit Dimensions
13
Unit Clearances
13
Bottom Duct Openings (from Above)
14
Rear Duct Dimensions
14
Ductwork
15
Duct Covers
15
Predator ® Roof Curb Dimensions
15
Curbs
15
Condensate Drain
16
Compressors
16
Filters
16
Side Panels with Hole Plugs
16
Return Downflow Plenum with Panel
16
Discharge Panel in Place
16
Thermostat Wiring
17
Power and Control Wiring
17
Power Wiring Detail
17
Control Wire Sizes
17
Electronic Thermostat Field Wiring
18
Field Wiring 24 Volt Thermostat
18
Field Wiring Disconnect
19
Electrical Data - Dm090 (7-1/2 Ton) Without Power Convenience Outlet
19
Electrical Data - Dm090 (7-1/2 Ton) with Power Convenience Outlet
19
Electrical Data - Dm120 (10 Ton) Without Power Convenience Outlet
20
Electrical Data - Dm120 (10 Ton) with Power Convenience Outlet
20
Electrical Data - Dm150 (12-1/2 Ton) Without Power Convenience Outlet
20
Electrical Data - Dm150 (12-1/2 Ton) with Power Convenience Outlet
20
Options/Accessories
21
Electric Heat Accessories
21
Electric Heat Option
21
Motorized Outdoor Damper
21
Physical Data
21
Minimum Supply Air Cfm
21
Economizer
22
Power Exhaust
22
Rain Hood
22
Economizer and Power Exhaust Set Point Adjustments and Information
22
Minimum Position Adjustment
22
Enthalpy Set Point Adjustment
22
Power Exhaust Damper Set Point (with or Without Power Exhaust)
22
Indoor Air Quality Aq
22
Enthalpy Set Point Chart
23
Honeywell Economizer Control W7212
23
Phasing
24
Blower Rotation
24
Belt Tension
24
Belt Adjustment
24
Supply Air Limitations
24
Blower Performance
25
Ton Standard Motor down Shot Blower Performance
25
Ton Optional Motor down Shot Blower Performance
25
Blower Performance
26
Ton Standard Motor down Shot Blower Performance
26
Blower Performance
27
Blower Performance
28
Blower Performance
29
Blower Performance
30
Air Balance
31
Checking Air Quantity
31
Method One
31
Method Two
31
Indoor Blower Specifications
31
Supply Air Drive Adjustment
32
Dry Coil Delta P
32
Operation
33
Sequence of Operations Overview
33
Additional Static Resistance
33
Motor Sheave Datum Diameters
33
Cooling Sequence of Operation
34
Continuous Blower
34
Intermittent Blower
34
No Outdoor Air Options
34
Economizer with Single Enthalpy Sensor
34
Economizer with Dual Enthalpy Sensors
34
Economizer with Power Exhaust
34
Motorized Outdoor Air Dampers
34
Cooling Operation Errors
35
High-Pressure Limit Switch
35
Low-Pressure Limit Switch
35
Freezestat
35
Low Ambient Cooling
35
Safety Controls
35
Compressor Protection
35
Flash Codes
36
Reset
36
Electric Heating Sequence of Operations
36
Electric Heating Operation Errors
36
Temperature Limit
36
Safety Controls
36
Limit Switch (Ls)
36
Electric Heat Antictpator Setpoints
36
Electric Heat Limit Setting
36
Electric Heat Anticipator Setpoints
36
Start-Up (Cooling)
37
Prestart Check List
37
Operating Instructions
37
Post Start Check List
37
Charging the Unit
37
34 7.5 Ton Standard Efficiency Superheat Charging
37
10 Ton Standard Efficiency Superheat Charging
38
Normal Maintenance
39
General
39
Filters
39
Motors
39
Outdoor Coil
39
Troubleshooting
39
Predator ® Flash Codes
39
Basic Troubleshooting Flowchart
40
Unit Control Board Flash Codes
40
Cooling Troubleshooting Guide
41
York PREDATOR DM 150 Installation Manual (44 pages)
SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE ELECTRIC UNITS
Brand:
York
| Category:
Air Conditioner
| Size: 1.53 MB
Table of Contents
Table of Contents
2
General
5
Safety Considerations
5
Inspection
5
Reference
5
Approvals
5
Nomenclature
6
Installation
10
Installation Safety Information
10
Preceding Installation
10
Limitations
10
Unit Shipping Bracket
10
Condenser Covering
10
Compressor Section
10
Location
11
Rigging and Handling
11
Unit Voltage Limitations
11
Unit Temperature Limitations
11
Clearances
12
Unit 4 Point Load
12
Unit 6 Point Load
12
Unit Center of Gravity
12
Unit Weights
12
Point Load Weight
12
Unit Dimensions
13
Unit Clearances
13
Bottom Duct Openings (from Above)
14
Rear Duct Dimensions
14
Ductwork
15
Duct Covers
15
Predator ® Roof Curb Dimensions
15
Sunline™ to Predator ® Transition Roof
15
Curbs
15
Condensate Drain
16
Compressors
16
Filters
16
Side Panels with Hole Plugs
16
Return Downflow Plenum with Panel
16
Discharge Panel in Place
16
Thermostat Wiring
17
Power and Control Wiring
17
Power Wiring Detail
17
Control Wire Sizes
17
Electronic Thermostat Field Wiring
18
Field Wiring 24 Volt Thermostat
18
Field Wiring Disconnect
19
Electrical Data - Dm090 (7-1/2 Ton) Without Power Convenience Outlet
19
Electrical Data - Dm090 (7-1/2 Ton) with Power Convenience Outlet
19
Electrical Data - Dm120 (10 Ton) Without Power Convenience Outlet
20
Electrical Data - Dm120 (10 Ton) with Power Convenience Outlet
20
Electrical Data - Dm150 (12-1/2 Ton) Without Power Convenience Outlet
20
Electrical Data - Dm150 (12-1/2 Ton) with Power Convenience Outlet
20
Options/Accessories
21
Electric Heat Accessories
21
Electric Heat Option
21
Motorized Outdoor Damper
21
Physical Data
21
Minimum Supply Air Cfm
21
Economizer
22
Power Exhaust
22
Rain Hood
22
Economizer and Power Exhaust Set Point Adjustments and Information
22
Minimum Position Adjustment
22
Enthalpy Set Point Adjustment
22
Power Exhaust Damper Set Point (with or Without Power Exhaust)
22
Indoor Air Quality Aq
22
Enthalpy Set Point Chart
23
Honeywell Economizer Control W7212
23
Phasing
24
Blower Rotation
24
Belt Tension
24
Belt Adjustment
24
Supply Air Limitations
24
Ton Optional Motor down Shot Blower Performance
25
Ton Standard Motor down Shot Blower Performance
25
Blower Performance
26
Ton Standard Motor down Shot Blower Performance
26
Blower Performance
28
Blower Performance
30
Air Balance
31
Checking Air Quantity
31
Method One
31
Method Two
31
Indoor Blower Specifications
31
Supply Air Drive Adjustment
32
Dry Coil Delta P
32
Operation
33
Sequence of Operations Overview
33
Additional Static Resistance
33
Motor Sheave Datum Diameters
33
Cooling Sequence of Operation
34
Continuous Blower
34
Intermittent Blower
34
No Outdoor Air Options
34
Economizer with Single Enthalpy Sensor
34
Economizer with Dual Enthalpy Sensors
34
Economizer with Power Exhaust
34
Motorized Outdoor Air Dampers
34
Cooling Operation Errors
35
High-Pressure Limit Switch
35
Low-Pressure Limit Switch
35
Freezestat
35
Low Ambient Cooling
35
Safety Controls
35
Compressor Protection
35
Flash Codes
36
Reset
36
Electric Heating Sequence of Operations
36
Electric Heating Operation Errors
36
Temperature Limit
36
Safety Controls
36
Limit Switch (Ls)
36
Electric Heat Antictpator Setpoints
36
Electric Heat Limit Setting
36
Electric Heat Anticipator Setpoints
36
Start-Up (Cooling)
37
Prestart Check List
37
Operating Instructions
37
Post Start Check List
37
Charging the Unit
37
Charging
38
Normal Maintenance
39
General
39
Filters
39
Motors
39
Outdoor Coil
39
Troubleshooting
39
Predator ® Flash Codes
39
Basic Troubleshooting Flowchart
40
Unit Control Board Flash Codes
40
Cooling Troubleshooting Guide
41
Advertisement
York PREDATOR DM 150 Technical Manual (48 pages)
STANDARD EFFICIENCY SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS 6-1/2, 7-1/2, 8-1/2, 10 and 12-1/2 NOMINAL TONS 9.0 EER
Brand:
York
| Category:
Air Conditioner
| Size: 4.44 MB
Table of Contents
Table of Contents
2
Description
3
Features
3
Factory Installed Options
5
Field Installed Accessories
6
Nomenclature
10
DM Physical Data
11
DM Capacity Ratings
12
Unit Voltage Limitations
12
Cooling Capacity Dm078 (6-1/2 Ton) Unit
13
Cooling Capacity Dm090 (7-1/2 Ton) Unit
14
Cooling Capacity Dm102 (8-1/2 Ton) Unit
15
Cooling Capacity Dm120 (10 Ton) Unit
16
Cooling Capacity Dm150 (12-1/2 Ton) Unit
17
Electrical Data Dm078 (6-1/2 Ton) Std Efficiency W/O Pwrd Convenience Outlet
18
Electrical Data Dm078 (6-1/2 Ton) Std Efficiency with Pwrd Convenience Outlet
18
W/Power Exhaust
19
Electrical Data - Dm090 (7-1/2 Ton) Standard Efficiency W/O Pwrd Conv. Outlet
19
Electrical Data - Dm090 (7-1/2 Ton) Standard Efficiency W/Pwrd Conv. Outlet
19
Electrical Data Dm102 (8-1/2 Ton) Std Efficiency W/O Pwrd Convenience Outlet
20
Electrical Data Dm102 (8-1/2 Ton) Std Efficiency with Pwrd Convenience Outlet
20
Exhaust
21
Electrical Data Dm120 (10 Ton) Std Efficiency W
21
Electrical Data Dm120 (10 Ton) Std Efficiency with Pwrd Convenience Outlet
21
Electrical Data Dm150 (12-1/2 Ton) Std Efficiency W/O Pwrd Convenience Outlet
22
Electrical Data Dm150 (12-1/2 Ton) Std Efficiency W/Pwrd Convenience Outlet
22
Electric Heat Multipliers
22
Performance
22
Additional Static Resistance Dm078, 120
33
Additional Static Resistance Dm090, 102
33
Electric Heat Minimum Supply Air Cfm
34
Indoor Blower Specifications
34
Unit 4 Point Load
35
Unit Center of Gravity
35
Unit 6 Point Load
35
Unit Dimensions
36
Unit Weight
36
Unit Height
36
Unit Clearances
36
Predator ® Roof Curb Dimensions
37
Sunline™ to Predator
38
Transition Roof
38
Curbs
38
Bottom Duct Openings (from Above)
38
Rear Duct Dimensions
39
Downflow Economizer Hood Detail
39
Factory Installed Downflow Economizer
40
Field Installed Downflow Economizer
40
Economizer Usage
40
Field Installed Horizontal Economizer
41
Slab Economizer Downflow W/Power
41
Slab Economizer End Return W/Power
42
Cooling Unit with Gas Heat Wiring 230 Volt
43
Diagram
43
Cooling Unit With/Without Electric Heat
44
Wiring Diagram
44
Cooling Unit with Gas Heat Wiring 460, 575 Volt and 50 Hz Diagram
45
Guide Specifications
46
Predator ® Component Location
46
W/Power Exhaust
48
Exhaust
48
Power Exhaust Specifications
48
York PREDATOR DM 150 Technical Manual (36 pages)
SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS 7-1/2, 10, 12-1/2 NOMINAL TONS 9.0 - 10.0 EER 380/415-3-50
Brand:
York
| Category:
Air Conditioner
| Size: 3.69 MB
Table of Contents
Table of Contents
2
Description
3
Features
3
Factory Installed Options
5
Field Installed Accessories
6
Roof Curb
7
Nomenclature
8
Metric
8
Physical Data
12
Capacity Ratings Imperial
13
Capacity Ratings Metric
13
Cooling Capacity 7-1/2 Ton Unit - Imperial
14
Cooling Capacity 26.4 Kw Unit - Metric
15
Cooling Capacity 10 Ton Unit - Imperial
16
Cooling Capacity 35.1 Kw Unit - Metric
17
Cooling Capacity 12-1/2 Ton Unit - Imperial
18
Cooling Capacity 43.9 Kw Unit - Metric
19
Electrical Data 7-1/2 Ton
20
Electrical Data 10 Ton
20
Electrical Data 12-1/2 Ton
20
Blower Performance 7-1/2 Ton Standard Motor - Side Duct (Imperial)
21
Blower Performance 7-1/2 Ton Standard Motor - Side Duct (Metric)
21
Blower Performance 7-1/2 Ton Optional Motor - Side Duct (Imperial)
21
Blower Performance 7-1/2 Ton Optional Motor - Side Duct (Metric)
22
Blower Performance 10 Ton Standard Motor - Side Duct (Imperial)
22
Blower Performance 10 Ton Standard Motor - Side Duct (Metric)
22
Blower Performance 10 Ton Optional Motor - Side Duct (Imperial)
23
Blower Performance 10 Ton Optional Motor - Side Duct (Metric)
23
Blower Performance 12-1/2 Ton - Side Duct (Imperial)
24
Blower Performance 12-1/2 Ton - Side Duct (Metric)
24
Blower Performance 7-1/2 Ton Standard Motor - Downshot (Imperial)
25
Blower Performance 7-1/2 Ton Standard Motor - Downshot (Metric)
25
Blower Performance 7-1/2 Ton Optional Motor - Downshot (Imperial)
25
Blower Performance 7-1/2 Ton Optional Motor - Downshot (Metric)
26
Blower Performance 10 Ton Standard Motor - Downshot (Imperial)
26
Blower Performance 10 Ton Standard Motor - Downshot (Metric)
26
Blower Performance 10 Ton Optional Motor - Downshot (Imperial)
27
Blower Performance 10 Ton Optional Motor - Downshot (Metric)
27
Blower Performance 12-1/2 Ton - Downshot
28
Additional Static Resistance (Imperial)
29
- Imperial
30
- Metric
30
Additional Static Resistance (Metric)
30
Electric Heat Minimum Supply Air
30
Unit 4 Point Load
31
Unit Center of Gravity
31
Unit 6 Point Load
31
Indoor Blower Specifications
31
Point Load Weight
31
Unit Weight
31
Unit Dimensions
32
Unit Clearances
32
Predator ® Roof Curb Dimensions
33
Sunline™ to Predator ® Transition
33
Bottom Duct Openings (from Above)
34
Rear Duct Dimensions
34
Cooling Unit with Gas Heat Wiring
35
Diagram
35
Cooling Unit With/Without Electric Heat
36
York PREDATOR DM 150 Installation Instruction (45 pages)
SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE ELECTRIC UNITS
Brand:
York
| Category:
Air Conditioner
| Size: 1.09 MB
Table of Contents
Product Nomenclature
5
General
6
Installation
7
Location
8
Rigging and Handling
9
Horizontal Economizer
10
Unit Dimensions
11
Bottom Duct Openings
12
Predator™ Roof Curb Dimensions
13
Ductwork
14
Power and Control Wiring
15
Field Wiring 24 Volt Thermostat
16
Predator 380V-3-60 Hz
17
Accessories
18
Set Point Adjustment
19
Start-Up
20
Air Balance
25
Supply Air Drive Adjustment
28
Cooling Operation Instructions
29
Protection
30
Freezestat
31
Normal Maintenance
33
Unit Control Board Flash Codes
34
Basic Troubleshooting Flowchart
35
Trip Failure Flow Chart
36
Cooling Operations
37
Advertisement
Related Products
York PREDATOR DM 120
York DM 180
York PREDATOR DM 102
York DM 300
York DM 060
York DM 036
York DM 048
York Saber DMS-480
York Saber DMS-600
York Saber DMS-420
York Categories
Air Conditioner
Heat Pump
Chiller
Furnace
Air Handlers
More York Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL