Sign In
Upload
Manuals
Brands
Endress+Hauser Manuals
Measuring Instruments
Proline Promass 80
Endress+Hauser Proline Promass 80 Manuals
Manuals and User Guides for Endress+Hauser Proline Promass 80. We have
7
Endress+Hauser Proline Promass 80 manuals available for free PDF download: Operating Instructions Manual, Description Of Device Functions, Brief Operating Instructions
Endress+Hauser Proline Promass 80 Operating Instructions Manual (178 pages)
Coriolis Mass Flow Measuring System, PROFIBUS DP/PA
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 2.94 MB
Table of Contents
Table of Contents
7
1 Safety Instructions
9
Designated Use
9
Installation, Commissioning and Operation
9
Operational Safety
9
Return
10
Notes on Safety Conventions and Icons
10
2 Identification
11
Device Designation
11
Nameplate of the Transmitter
11
Nameplate of the Sensor
12
Nameplate for Connections
13
Certificates and Approvals
14
Registered Trademarks
14
3 Installation
15
Incoming Acceptance, Transport and Storage
15
Incoming Acceptance
15
Transport
15
Storage
16
Installation Conditions
16
Dimensions
16
Mounting Location
16
Orientation
18
Heating
20
Thermal Insulation
21
Inlet and Outlet Runs
21
Vibrations
21
Limiting Flow
21
Installation Instructions
22
Turning the Transmitter Housing
22
Installing the Wall-Mount Transmitter
23
Housing
23
Turning the Local Display
25
Post-Installation Check
25
4 Wiring
26
PROFIBUS Cable Specifications
26
PROFIBUS DP Cable Specifications
26
PROFIBUS PA Cable Specifications
27
Shielding and Grounding
29
Connecting the Remote Version
30
Connecting Connecting Cable for Sensor/Transmitter
30
Cable Specification for Connecting Cable
30
Connecting the Measuring Unit
31
Terminal Assignment
31
Transmitter Connection
32
PROFIBUS DP Connection Diagram
33
PROFIBUS PA Connection Diagram
35
Degree of Protection
37
Post-Connection Check
38
Operation
39
Quick Operation Guide
39
Local Display
40
Display and Operating Elements
40
Display (Operating Mode)
41
Additional Display Functions
41
Icons
42
Controlling the Batching Processes Using the Local Display
44
Brief Operating Instructions to the Function Matrix
45
General Notes
46
Enabling the Programming Mode
46
Disabling the Programming Mode
46
Error Messages
47
Type of Error
47
Error Message Type
47
Operating Options
48
Fieldcare
48
Operating Program
48
Tof Tool - Fieldtool Package
48
SIMATIC PDM" (Siemens)
48
Operating Program
49
Device Description Data for Operating Programs
49
PROFIBUS DP Hardware Settings
51
Configuring the Write Protection
51
Configuring the Device Address
52
Configuring the Terminating Resistors
53
Current Output Configuration
54
Relay Output Configuration
55
PROFIBUS PA Hardware Settings
56
Configuring the Write Protection
56
Configuring the Device Address
57
6 Commissioning
58
Function Check
58
Switching on the Measuring Device
58
Quick Setup
59
Quick Setup "Commissioning
59
Quick Setup "Batching
61
Quick Setup "Pulsating Flow
65
Quick Setup "Gas Measurement
68
Quick Setup "Communication
70
Data Back-Up with "T-DAT SAVE/LOAD
72
Device Configuration
73
Concentration Measurement
73
Advanced Diagnostic Functions
78
Commissioning the PROFIBUS Interface
80
PROFIBUS DP Commissioning
80
PROFIBUS PA Commissioning
84
PROFIBUS System Integration
86
Device Master File (GSD File)
86
PROMASS 63 with Profile Version 2.0
89
PROFIBUS DP Cyclic Data Exchange
90
Block Model
90
Modules for Cyclic Data Exchange
90
Configuration Information for Integrating Modules
99
Configuration Examples with
100
Simatic S7 HW-Konfig
100
PROFIBUS PA Cyclic Data Exchange
103
Block Model
103
Modules for Cyclic Data Exchange
103
Configuration Information for Integrating Modules
108
Configuration Examples with
109
Simatic S7 HW-Konfig
109
Adjust
112
Zero Point Adjustment
112
Density Adjustment
113
Purge and Pressure Monitoring Connections
115
Data Storage Device (Historom), F-CHIP
115
Historom/S-DAT (Sensor-DAT)
115
Historom/T-DAT (Transmitter-DAT)
115
F-CHIP (Function-Chip)
115
7 Maintenance
116
Exterior Cleaning
116
Cleaning with Pigs (Promass H, I)
116
Replacing Seals
116
8 Accessories
117
Device-Specific Accessories
117
Measuring Principle-Specific Accessories
117
Service-Specific Accessories
118
9 Trouble-Shooting
119
Trouble-Shooting Instructions
119
System Error Messages
121
Displaying the Device Status on
121
Profibus
122
List of System Error Messages
122
Process Error Messages
132
Displaying the Device Status on
132
Profibus
132
List of Process Error Messages
132
Process Errors Without Messages
135
Response of Outputs to Errors
136
Spare Parts
137
Profibus Dp
137
Profibus Pa
138
Removing and Installing Printed Circuit
139
Boards
139
Replacing the Device Fuse
143
Return
144
Disposal
144
Software History
145
10 Technical Data
147
Technical Data at a Glance
147
Applications
147
Function and System Design
147
Input
147
PROFIBUS DP Output
149
Power Supply
150
Performance Characteristics
151
Operating Conditions: Installation
157
Operating Conditions: Environment
157
Operating Conditions: Process
158
10.1.10 Mechanical Construction
166
10.1.11 Human Interface
169
10.1.12 Certificates and Approvals
170
10.1.13 Ordering Information
171
10.1.14 Accessories
171
10.1.15 Documentation
171
Index
172
Advertisement
Endress+Hauser Proline Promass 80 Operating Instructions Manual (130 pages)
PROFIBUS PA Coriolis Mass Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 2.22 MB
Table of Contents
Operating Instructions
1
Table of Contents
3
1 Safety Instructions
5
Designated Use
5
Installation, Commissioning and Operation
5
Operational Safety
6
Return
6
Notes on Safety Conventions and Icons
6
2 Identification
7
Device Designation
7
Nameplate of the Transmitter
8
Nameplate of the Sensor
9
Nameplate for Connections
10
Certificates and Approvals
11
Registered Trademarks
11
3 Installation
12
Incoming Acceptance, Transport and Storage
12
Incoming Acceptance
12
Transport
12
Storage
13
Installation Conditions
13
Dimensions
13
Mounting Location
13
Orientation
15
Special Installation Instructions
17
Heating
19
Thermal Insulation
20
Inlet and Outlet Runs
20
Vibrations
20
Limiting Flow
20
Installation Instructions
21
Turning the Transmitter Housing
21
Installing the Wall-Mount Housing
22
Turning the Local Display
24
Post-Installation Check
24
4 Wiring
25
PROFIBUS PA Cable Specifications
25
Cable Type
25
Maximum Overall Cable Length
26
Maximum Spur Length
26
Number of Field Devices
26
Bus Termination
26
Further Information
26
Shielding and Grounding
27
Connecting the Remote Version
28
Connecting Connecting Cable for Sensor
28
Transmitter
28
Cable Specification for Connecting Cable
28
Connecting the Measuring Unit
29
Terminal Assignment
29
Transmitter Connection
29
Fieldbus Connector
31
Degree of Protection
33
Post-Connection Check
34
5 Operation
35
Quick Operation Guide
35
Local Display
36
Display and Operating Elements
36
Icons
37
Brief Operating Instructions on the Function Matrix
38
General Notes
39
Enabling the Programming Mode
39
Disabling the Programming Mode
39
Error Messages
40
Type of Error
40
Error Message Type
40
Operating Options
41
Fieldcare
41
Operating Program
41
SIMATIC PDM" (Siemens)
41
Device Description Files for Operating Programs
42
PROFIBUS PA Hardware Settings
43
Hardware Write Protection
43
Configuring the Device Address
44
6 Commissioning
45
Function Check
45
Switching on the Measuring Device
45
Quick Setup
46
Quick Setup "Commissioning
46
Commissioning the PROFIBUS PA Interface
47
PROFIBUS PA System Integration
49
Device Master File (GSD File)
49
Selecting the GSD File in the Measuring Device
51
Maximum Numbers of Writes
51
Cyclic Data Transmission PROFIBUS PA
52
Block Model
52
Modules for Cyclic Data Transmission
52
Description of the Modules
53
Configuration Examples with Simatic S7 HW-Konfig
59
Adjustment
61
Zero Point Adjustment
61
Density Adjustment
63
Rupture Disk
64
Purge and Pressure Monitoring Connections
64
Data Storage Device (Historom)
64
Historom/S-DAT (Sensor-DAT)
64
7 Maintenance
65
Exterior Cleaning
65
Cleaning with Pigs (Promass H, I, S, P)
65
Replacing Seals
65
8 Accessories
66
Device-Specific Accessories
66
Measuring Principle-Specific Accessories
66
Service-Specific Accessories
67
9 Troubleshooting
68
Troubleshooting Instructions
68
System Error Messages
70
Profibus Pa
70
List of System Error Messages
71
Process Error Messages
76
Profibus Pa
76
List of Process Error Messages
76
Process Errors Without Messages
78
Spare Parts
79
Removing and Installing Printed
80
Circuit Boards
80
Replacing the Device Fuse
84
Return
85
Disposal
85
Software History
85
10 Technical Data
87
Technical Data at a Glance
87
Applications
87
Function and System Design
87
Input
87
Output
90
Power Supply
91
Performance Characteristics
92
Installation
108
Environment
108
Process
109
10.1.10 Mechanical Construction
118
10.1.11 Human Interface
123
10.1.12 Certificates and Approvals
123
10.1.13 Ordering Information
124
10.1.14 Accessories
124
10.1.15 Supplementary Documentation
124
Index
125
Endress+Hauser Proline Promass 80 Operating Instructions Manual (162 pages)
Coriolis Mass Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 4.09 MB
Table of Contents
Table of Contents
5
Safety Instructions
7
Designated Use
7
Installation, Commissioning and Operation
7
Operational Safety
7
Return
8
Notes on Safety Conventions and Icons
8
Identification
9
Device Designation
9
Nameplate of the Transmitter
9
Nameplate of the Sensor
10
CE Mark, Declaration of Conformity
10
Registered Trademarks
11
Installation
13
Incoming Acceptance, Transport and Storage
13
Incoming Acceptance
13
Transport
13
Storage
14
Installation Conditions
14
Dimensions
14
Mounting Location
14
Orientation
16
Heating
18
Thermal Insulation
19
Inlet and Outlet Runs
19
Vibrations
19
Limiting Flow
19
Installation Instructions
20
Turning the Transmitter Housing
20
Installing the Wall-Mount Transmitter Housing
21
Turning the Local Display
22
Post Installation Check
22
Wiring
23
Connecting the Remote Version
23
Connecting the Sensor
23
Cable Specifications
24
Connecting the Measuring Unit
25
Connecting the Transmitter
25
Terminal Assignment
27
HART Connection
28
Degree of Protection
29
Post Connection Check
30
Operation
31
Display and Operating Elements
31
Brief Operating Instructions to the Function Matrix
32
General Notes
33
Enabling the Programming Mode
33
Disabling the Programming Mode
33
Display of Error Messages
34
Communication
35
Operating Options
35
Device and Process Variables
36
Universal / Common Practice HART Commands
37
Device Status / Error Messages
43
Commissioning
49
Function Check
49
Switching on the Measuring Device
49
Quick Setup "Commissioning
50
Zero Point Adjustment
52
Density Adjustment
54
Current Output 1: Active/Passive
55
Current Outputs 2: Active/Passive
56
Purge and Pressure Monitoring Connections
57
Maintenance
58
Accessories
59
Trouble-Shooting
61
Trouble-Shooting Instructions
61
System Error Messages
62
Process Error Messages
67
Process Errors Without Messages
69
Response of Outputs to Errors
70
Spare Parts
72
Removing and Installing Printed Circuit Boards
73
Replacing the Device Fuse
77
Software History
78
Technical Data
81
Technical Data at a Glance
81
Applications
81
Function and System Design
81
Input
81
Output
83
Auxiliary Energy
83
Performance Characteristics
84
Operating Conditions
88
Mechanical Construction
97
Human Interface
100
10.1.10 Certificates and Approvals
100
10.1.11 Ordering Information
100
10.1.12 Accessories
101
10.1.13 Documentation
101
Dimensions: Wall-Mount Housing
102
Dimensions: Stainless Steel Field Housing
102
Dimensions: Remote Version (Promass F, M, A, H, I)
103
Dimensions: Remote Version (Promass E)
103
Dimensions: Remote Version for Heating
103
Dimensions: High-Temperature Version
104
(Compact)
104
(Remote)
104
Dimensions: Promass F
105
10.10 Dimensions: Promass M
115
10.11 Dimensions: Promass E
129
10.12 Dimensions: Promass a
138
10.13 Dimensions: Promass H
144
10.14 Dimensions: Promass I
146
Index
157
Advertisement
Endress+Hauser Proline Promass 80 Operating Instructions Manual (114 pages)
Coriolis Mass Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 2.04 MB
Table of Contents
Table of Contents
3
1 Safety Instructions
5
Designated Use
5
Installation, Commissioning and Operation
5
Operational Safety
6
Return
6
Notes on Safety Conventions and Icons
6
2 Identification
7
Device Designation
7
Nameplate of the Transmitter
8
Nameplate of the Sensor
9
Nameplate for Connections
10
Certificates and Approvals
11
Registered Trademarks
11
3 Installation
12
Incoming Acceptance, Transport and Storage
12
Incoming Acceptance
12
Transport
12
Storage
13
Installation Conditions
13
Dimensions
13
Mounting Location
13
Orientation
15
Special Installation Instructions
17
Heating
19
Thermal Insulation
20
Inlet and Outlet Runs
20
Vibrations
20
Limiting Flow
20
Installation
21
Turning the Transmitter Housing
21
Installing the Wall-Mount Housing
22
Turning the Local Display
24
Post Installation Check
24
4 Wiring
25
Connecting the Remote Version
25
Connecting the Sensor/Transmitter
25
Cable Specification, Connecting Cable
26
Connecting the Measuring Unit
26
Transmitter Connection
26
Terminal Assignment
28
HART Connection
29
Degree of Protection
30
Post Connection Check
30
5 Operation
31
Display and Operating Elements
31
Brief Operating Instructions to the Function Matrix
32
General Notes
33
Enabling the Programming Mode
33
Disabling the Programming Mode
33
Error Messages
34
Type of Error
34
Error Message Type
34
Communication
35
Operating Options
35
Current Device Description Files
36
Device and Process Variables
36
HART Commands
37
Device Status / Error Messages
42
6 Commissioning
44
Function Check
44
Switching on the Measuring Device
44
Quick Setup
45
Commissioning" Quick Setup
45
Configuration
47
One Current Output: Active/Passive
47
Two Current Outputs: Active/Passive
48
Adjust
49
Zero Point Adjustment
49
Density Adjustment
51
Rupture Disk
52
Purge and Pressure Monitoring Connections
52
Data Storage Device (Historom)
52
Historom/S-DAT (Sensor-DAT)
52
7 Maintenance
53
Exterior Cleaning
53
Cleaning with Pigs (Promass H, I, S, P)
53
Replacing Seals
53
8 Accessories
54
Device-Specific Accessories
54
Measuring Principle-Specific Accessories
54
Communication-Specific Accessories
55
Service-Specific Accessories
55
9 Troubleshooting
56
Troubleshooting Instructions
56
System Error Messages
57
Process Error Messages
60
Process Errors Without Messages
61
Response of Outputs to Errors
62
Spare Parts
63
Removing and Installing Printed
64
Circuit Boards
64
Replacing the Device Fuse
68
Return
69
Disposal
69
Software History
69
10 Technical Data
71
Technical Data at a Glance
71
Applications
71
Function and System Design
71
Input
71
Output
74
Power Supply
75
Performance Characteristics
76
Operating Conditions: Installation
93
Operating Conditions: Environment
93
Operating Conditions: Process
94
10.1.10 Mechanical Construction
103
10.1.11 Human Interface
108
10.1.12 Certificates and Approvals
108
10.1.13 Ordering Information
109
10.1.14 Accessories
109
10.1.15 Documentation
109
Index
110
Endress+Hauser Proline Promass 80 Operating Instructions Manual (104 pages)
Coriolis Mass Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.93 MB
Table of Contents
Operating Instructions
1
Table of Contents
5
1 Safety Instructions
7
Designated Use
7
Installation, Commissioning and Operation
7
Operational Safety
7
Return
8
Notes on Safety Conventions and Icons
8
2 Identification
9
Device Designation
9
Nameplate of the Transmitter
9
Nameplate of the Sensor
10
Nameplate for Connections
11
Certificates and Approvals
11
Registered Trademarks
12
3 Installation
13
Incoming Acceptance, Transport and Storage
13
Incoming Acceptance
13
Transport
13
Storage
14
Installation Conditions
14
Dimensions
14
Mounting Location
14
Orientation
16
Heating
18
Thermal Insulation
19
Inlet and Outlet Runs
19
Vibrations
19
Limiting Flow
19
Installation Instructions
20
Turning the Transmitter Housing
20
Installing the Wall-Mount Transmitter Housing
21
Turning the Local Display
23
Post Installation Check
23
4 Wiring
24
Connecting the Remote Version
24
Connecting Connecting Cable for Sensor
24
Transmitter
24
Cable Specification Connecting Cable
25
Connecting the Measuring Unit
25
Transmitter Connection
25
Terminal Assignment
27
HART Connection
28
Degree of Protection
29
Post Connection Check
30
5 Operation
31
Display and Operating Elements
31
Brief Operating Instructions to the Function Matrix
32
General Notes
33
Enabling the Programming Mode
33
Disabling the Programming Mode
33
Error Messages
34
Type of Error
34
Error Message Type
34
Communication
35
Operating Options
36
Device and Process Variables
38
HART Commands
39
Device Status / Error Messages
44
6 Commissioning
49
Function Check
49
Switching on the Measuring Device
49
Application-Specific Commissioning
50
Quick Setup "Commissioning
50
Configuration
52
One Current Output: Active/Passive
52
Two Current Outputs: Active/Passive
53
Adjustment
54
Zero Point Adjustment
54
Density Adjustment
56
Purge and Pressure Monitoring Connections
57
Data Storage Device (Historom)
57
Historom/S-DAT (Sensor-DAT)
57
7 Maintenance
58
External Cleaning
58
Cleaning with Pigs (Promass H, I)
58
Replacing Seals
58
8 Accessories
58
Device-Specific Accessories
59
Measuring Principle-Specific Accessories
59
Communication-Specific Accessories
59
Service-Specific Accessories
60
9 Trouble-Shooting
61
Trouble-Shooting Instructions
61
System Error Messages
62
Process Error Messages
65
Process Errors Without Messages
66
Process Error Messages
67
Spare Parts
68
Removing and Installing Printed
69
Circuit Boards
69
Replacing the Device Fuse
73
Return
74
Disposal
74
Software History
74
10 Technical Data
76
Technical Data at a Glance
76
Applications
76
Function and System Design
76
Input
76
Output
78
Power Supply
78
Performance Characteristics
79
Operating Conditions: Installation
85
Operating Conditions: Environment
85
Operating Conditions: Process
86
10.1.10 Mechanical Construction
94
10.1.11 Human Interface
97
10.1.12 Certificates and Approvals
98
10.1.13 Ordering Information
99
10.1.14 Accessories
99
10.1.15 Documentation
99
Index
100
Endress+Hauser Proline Promass 80 Description Of Device Functions (68 pages)
Coriolis Mass Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.56 MB
Table of Contents
Table of Contents
3
Function Matrix Promass 80
5
The Function Matrix: Layout and Use
5
Group MEASURING VALUES
7
Group SYSTEM UNITS
8
Group QUICK SETUP
13
Group OPERATION
15
Group USER INTERFACE
17
Group TOTALIZER 1/2
20
Group HANDLING TOTALIZER
22
Group CURRENT OUTPUT 1/2
23
Group PULSE/FREQUENCY OUTPUT
29
Group STATUS OUTPUT
41
Information on the Response of the Status Output
43
Switching Action of the Status Output
44
Group STATUS INPUT
46
Group COMMUNICATION
48
Group PROCESS PARAMETER
49
Group SYSTEM PARAMETER
54
Group SENSOR DATA
57
Group SUPERVISION
59
Group SIMULATION SYSTEM
61
Group SENSOR VERSION
62
Factory Settings
63
SI Units (Not for USA and Canada)
63
US Units (Only for USA and Canada)
64
Endress+Hauser Proline Promass 80 Brief Operating Instructions (29 pages)
Coriolis flowmeter
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.34 MB
Table of Contents
Safety Instructions
3
Safety Conventions
4
Installation
5
Post-Installation
9
Post-Installation Check
12
Wiring
13
Connecting the Various Housing Types
14
Degree of Protection
15
Hardware Settings
16
Commissioning
18
Operation
19
Navigating Within the Function Matrix
20
Calling the Commissioning Quick Setup
21
Software Settings
22
Troubleshooting
23
Advertisement
Related Products
Endress+Hauser Proline Promass 83
Endress+Hauser Proline Prowirl 72
Endress+Hauser Proline Promass 84
Endress+Hauser Proline Prosonic Flow P
Endress+Hauser Proline Prosonic Flow W
Endress+Hauser Proline Prowirl 73
Endress+Hauser Proline Promass series
Endress+Hauser Proline Promag 10
Endress+Hauser Proline Promass 84F
Endress+Hauser Proline Promag 51
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL