Ferroli MODENA S HE Instructions For Use, Installation And Maintenance
Ferroli MODENA S HE Instructions For Use, Installation And Maintenance

Ferroli MODENA S HE Instructions For Use, Installation And Maintenance

Advertisement

Quick Links

MODENA S HE
INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE

Advertisement

Table of Contents
loading

Summary of Contents for Ferroli MODENA S HE

  • Page 1 MODENA S HE INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE...
  • Page 2 “This record must be completed and left with the end user”. Ferroli is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
  • Page 3: Table Of Contents

    MODENA S HE 1 Instructions ..........................4 1.1 Introduction............................. 4 1.2 Control panel ............................4 1.3 Turning ON and OFF..........................5 1.4 Adjustments............................6 2 Installation ..........................7 2.1 General Instructions ..........................7 2.2 Place of installation ..........................8 2.3 Plumbing connections ..........................8 2.4 Connection to the gas system ......................
  • Page 4: Instructions

    1. Instructions 1.1 Introduction Thank you for choosing the MODENA S HE, a FERROLI wall-mounted boiler the latest generation appliance, featuring advanced design and cutting-edge technology. MODENA S HE is a high-efficiency condensing pre-mix appliance for central heating and hot water production, run- ning on natural gas or LPG, generating extremely low emissions.
  • Page 5: Turning On And Off

    MODENA S HE Indication during boiler operation Central Heating mode The Central Heating heat demand (generated by the Room Thermostat or the Clock) is indicated by the flashing of the Hot Air symbol over the radiator (part. 13 and 14 - fig. 1). The display indicates the actual Central Heating water tem- perature (part.
  • Page 6: Adjustments

    MODENA S HE Turning off Press the on/off button (part. 7 - fig. 1) for 5 seconds. fig. 6 - Turning off When the boiler is turned off with this key, the p.c.b is still powered, heating operation is disabled and the display is off however the frost protection will still be active.
  • Page 7: Installation

    MODENA S HE 2. Installation 2.1 General Instructions This unit must only be used for its intended purpose. This unit is designed to heat water to a temperature below boiling point and must be connected to a heating system and/or a water supply system for domestic use, com- patible with its performance, characteristics and heating capacity.
  • Page 8: Place Of Installation

    MODENA S HE 2.2 Place of installation The combustion circuit is sealed with respect to the place of installation and therefore the unit can be in- stalled in any room. However, the place of installation must be sufficiently ventilated to prevent the creation of dangerous conditions in case of even slight gas leaks.
  • Page 9 MODENA S HE Shutoff valve kit The shutoff valves supplied (see fig. 10) must be installed between the boiler and heating system to allow the boiler to be isolated from the system if necessary. For installation, follow the instructions contained in the kit.
  • Page 10: Connection To The Gas System

    MODENA S HE Water treatment If treatment of the water is necessary, Ferroli recommends the exclusive use of specific products such as Fernox or Sentinel to be applied in compliance with the producer's instructions. For more information, please contact: Fernox Manufacturing Co. LTD.
  • Page 11 MODENA S HE Accessing electrical terminal block The electrical connections terminal block can be accessed after removing the casing. The layout of the terminals for the various connections is given in the wiring diagram in fig. 36. fig. 12 - Electrical terminal block Room thermostat (optional) Remove connections 5 - 6 if external control fitted.
  • Page 12 MODENA S HE Central heating Demand The heat demand can be controlled by the room thermostat (terminal 5-6) or by a switch line 230 V (terminal 5). Standard system For a general pipe layout and wiring diagram on the “S” and “Y” plan systems please see fig. 13, fig. 14, fig. 15 and fig.
  • Page 13 MODENA S HE MODENA “Y” Plan fig. 15 - Pipe layout Pre-Fitted flex Honeywell V4073H mid position from boiler N E L 230 Vac 1 2 3 4 5 6 7 8 9 10 Room Thermostat Cylinder Thermostat fig. 16 - Wiring diagram...
  • Page 14: Flue System

    The current standards and local regulations must be observed. Only a Ferroli flue system (with respective accessories) must be used with this unit, as required by BS 5440 and CE standards.
  • Page 15 MODENA S HE Other coaxial connections fig. 18 - Examples of connection with coaxial pipes ( = Air / = Fumes) For coaxial connection, fit the unit with one of the following starting accessories. For the wall hole dimensions, refer to section "4.1 Dimensions and connections"...
  • Page 16 MODENA S HE Connection with separate pipes fig. 20 - Examples of connection with separate pipes ( = Air / = Fumes) For the connection of separate ducts, fit the unit with the following starting accessory: Ø 81 Ø 81 fig.
  • Page 17 MODENA S HE Position of terminals D, E fig. 22 Minimum dimensions of fume exhaust terminals Directly under an opening, air inlet, openable window, etc. 300 mm Above an opening, air inlet, openable window, etc. 300 mm Horizontally to an opening, air inlet, openable window, etc.
  • Page 18: Condensate Drain Connection

    Connection to multiple flues or single flues with natural draught To connect the MODENA S HE boiler to a multiple flue or a single flue with natural draught, the flue or chimney must be expressly designed by professionally qualified technical personnel in conformity with the current standards and regulations.
  • Page 19 MODENA S HE Condensate drain If possible, the condensate should be conveyed inside the internal drainage system or pipe. For that purpose, use a supplied with pipe of at least 22 mm diameter and a trap with flexible connection the unit to facilitate connection of the condensate drain pipe.
  • Page 20: Service And Maintenance

    All adjustment, conversion, startup and maintenance operations described below must only be carried out by Qualified Per- sonnel (meeting the professional technical requirements prescribed by current regulations). FERROLI declines any liability for damage and/or injury caused by unqualified and unauthorised persons tampering with the unit.
  • Page 21: Start-Up

    MODENA S HE 3.2 Start-up Checks to be made at first lighting, and after all maintenance operations that involved disconnection from the systems or an operation on safety devices or parts of the boiler: Before lighting the boiler • Open any on-off valves between the boiler and the systems.
  • Page 22: Commisioning Instructions

    MODENA S HE 3.3 Commisioning instructions General PLEASE NOTE: The combustion for this appliance has been checked, adjusted and preset at the factory for operation on the gas type defined on the appliance data plate. Having checked: • That the boiler has been installed in accordance with these instructions, •...
  • Page 23: Routine Servicing, Maintenance & Repair

    MODENA S HE Measure the gas rate Measure the gas rate and check against following table: GAS RATES (NATURAL GAS) AFTER 10 MINUTES FROM COLD Maximum rate Minimum rate BOILER MODEL MODENA 18 S HE 1.84 65.07 0.42 14.85 MODENA 25 S HE 2.64...
  • Page 24 MODENA S HE Opening the casing To open the boiler casing, you need to follow the sequence given below and the instructions of fig. 29. 1. Using a screwdriver, partially unscrew the 2 screws “A” (fig. 28) 2. Lift the panel “B”...
  • Page 25 MODENA S HE If the combustion reading is greater than the acceptable value AND the integrity of the complete flue system and combustion circuit seals have been verified and the inlet gas pressure (and gas rate) have been verified, proceed as in section " Setting the Air/Gas Ratio valve" pag. 25.
  • Page 26: Troubleshooting

    MODENA S HE 3.5 Troubleshooting Diagnostics The boiler is equipped with an advanced self-diagnosis system. In case of a boiler fault, the display will flash together with the fault symbol (detail 11 - fig. 1) indicating the fault code. Certain faults cause permanent boiler shutdowns (marked with the letter “A”): to restore operation, press the RESET button (detail 6 - fig.
  • Page 27: Technical Data And Characteristics

    MODENA S HE 4. Technical data and characteristics 4.1 Dimensions and connections 35.5 131.5 fig. 32 - Dimensions and connections Heating system delivery Gas inlet Heating system return cod. 3541C360 - 04/2012 (Rev. 00)
  • Page 28: General View And Main Components

    MODENA S HE 4.2 General view and main components fig. 33 - General view Gas inlet 196 Condensate tray System delivery 278 Double sensor (Safety + Heating) System return 350 Fan/Burner Safety valve Heating circulating pump Automatic air vent Gas valve...
  • Page 29: Water Circuit

    MODENA S HE 4.3 Water circuit fig. 34 - Water circuit System delivery System return Safety valve Heating circulating pump Automatic air vent Expansion tank 114 Water pressure switch 154 Condensate outlet pipe 186 Return sensor Condensate Trap 278 Double sensor (Safety + Heating) 340 Bypass pipe cod.
  • Page 30: Technical Data Table

    MODENA S HE 4.4 Technical data table Data Unit MODENA 18 S HE MODENA 25 S HE CH Max Heat Input 17.4 25.0 CH Min Heat Input CH Max. Heat Output (80/60°C) 17.0 24.5 CH Min Heat Output (80/60°C) CH Max. Heat Output (50/30°C) 18.5...
  • Page 31: Diagrams

    MODENA S HE 4.5 Diagrams Head available for the system H [m H 1.000 1.500 2.000 Q [l/h] fig. 35 - Pressure loss 1 - 2 - 3 Pump selector positions (In order to obtain maximum hot water output the pump must be left in position 3) Boiler pressure losses cod.
  • Page 32: Wiring Diagram

    MODENA S HE 4.6 Wiring diagram REMOVE IF EXTERNAL CONTROL FITTED 230 Vac FUSE 3.15A 250V T° T° 186 44 22:00 REMOVE TO CONNECT CLOCK fig. 36 - Wiring diagram Important: Before connecting the room thermostat or the remote timer control, remove the jumper on the terminal block.
  • Page 34 Failure to install and commission according to the manufacturer’s instructions and complete this Benchmark Commissioning Checklist will invalidate the warranty. This does not affect the customer’s statutory rights. If yes, and if required by the manufacturer, has a water scale reducer been fitted? CONDENSING BOILERS ONLY The condensate drain has been installed in accordance with the manufacturer’s instructions and/or BS5546/BS6798 If the condensate pipe terminates externally has the pipe diameter been increased and weatherproof insulation fitted?
  • Page 35: Service Record

    Service Record It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 36 Before contacting Ferroli please have available the completed BENCHMARK document (located in the back of this manual), boiler serial number and model detail. For Technical assistance during the installation, call our Technical Service Helpline on 0871 559 2927. You will required to provide your Gas Safe Register Number.

Table of Contents