11. AUTO CALIBRATION
11.6 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the
result window will show correction values per every power level and gain code and the same
measure is performed per every frequency.
11.7 APC
This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.
11.8 ADC
This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table will be reset.
11.9 Target Power
BAND
EGSM 900
DCS1800
PCS 1900
LGE Internal Use Only
Description
Low
Channel
975
Frequency
880.2 MHz
Max power
33.0 dBm
Channel
512
Frequency
1710.2 MHz
Max power
30.0 dBm
Channel
512
Frequency
1850.2 MHz
Max power
30.0 dBm
- 162 -
13. AUTO CALIBRATION
Middle
37
897.4 MHz
33.0 dBm
699
1747.6 MHz
30.0 dBm
661
1880 MHz
30.0 dBm
153/158
Copyright © 2010 LG Electronics. Inc. All right reserved.
High
124
914.8 MHz
33.0 dBm
885
1784.8 MHz
30.0 dBm
810
1909.8 MHz
30.0 dBm
Only for training and service purposes