TUHM AIRFLOW - HEATING
*UHMB060ACV3VB^ Furnace Heating Airflow (CFM) and Power (watts) vs. External Static Pressure With Filter
Airflow
Target Airflow
Setting
(See Note 5)
Low
465
Medium Low
504
40%
(low)
Heat
Medium**
538
High
605
Low
623
Medium Low
675
65%
(medium)
Heat
Medium**
720
High
810
Low
830
Medium Low
900
100%
(high)
Heat
Medium**
960
High
1080
*UHMB080ACV3VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow
Target Airflow
Setting
(See Note 5)
Low
571
Medium Low
643
40%
(low)
Heat
Medium**
714
High
821
Low
806
Medium Low
907
65%
(medium)
Heat
Medium**
1008
High
1159
Low
1120
Medium Low
1260
100%
(high)
Heat
Medium**
1400
High
1610
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z".
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium
heat are percentages of high heat and are not field selectable.
8
External Static Pressure
0.1
0.3
0.5
CFM
393
504
512
Temp. Rise
73
57
Watts
43
81
112
CFM
435
541
549
Temp. Rise
66
53
Watts
46
86
119
CFM
472
573
580
Temp. Rise
61
50
Watts
50
90
125
CFM
545
636
644
Temp. Rise
53
45
Watts
60
103
141
CFM
565
653
660
Temp. Rise
68
59
Watts
64
107
145
CFM
622
703
710
Temp. Rise
62
55
Watts
75
120
161
CFM
671
745
752
Temp. Rise
58
52
Watts
86
133
175
CFM
769
831
837
Temp. Rise
50
46
Watts
114
164
210
CFM
791
849
856
Temp. Rise
65
61
Watts
121
171
219
CFM
867
916
922
Temp. Rise
59
56
Watts
148
201
251
CFM
932
972
979
Temp. Rise
55
53
Watts
174
229
282
CFM
1063
1086
1092
Temp. Rise
48
47
Watts
236
295
353
External Static Pressure
0.1
0.3
0.5
CFM
512
564
581
Temp. Rise
70
63
62
Watts
45
77
112
CFM
586
634
649
Temp. Rise
61
56
55
Watts
57
90
129
CFM
661
704
717
Temp. Rise
54
51
50
Watts
71
106
148
CFM
772
809
819
Temp. Rise
46
44
44
Watts
99
136
184
CFM
757
794
805
Temp. Rise
67
63
63
Watts
95
132
179
CFM
862
893
901
Temp. Rise
59
56
56
Watts
127
165
217
CFM
967
992
997
Temp. Rise
52
51
51
Watts
165
205
262
CFM
1125
1139
1141
Temp. Rise
45
44
44
Watts
233
276
341
CFM
1084
1101
1104
Temp. Rise
65
64
63
Watts
214
256
319
CFM
1230
1238
1237
Temp. Rise
57
57
57
Watts
286
331
401
CFM
1376
1375
1370
Temp. Rise
51
51
51
Watts
369
418
495
CFM
1595
1580
1570
Temp. Rise
44
44
45
Watts
398
470
522
0.7
0.9
546
560
56
53
51
142
140
580
593
52
50
49
150
148
609
621
50
47
46
159
155
667
676
45
43
43
177
169
682
691
58
57
56
182
172
727
734
54
53
53
199
183
766
771
51
50
50
215
192
843
846
46
46
46
250
211
861
862
60
60
60
258
215
921
920
56
56
56
290
230
973
970
53
53
53
319
243
1076
1069
47
48
48
384
268
0.7
0.9
538
572
66
62
109
146
606
634
59
56
127
177
673
696
53
51
146
207
774
789
46
45
176
253
760
776
66
65
172
246
855
864
59
58
202
289
951
951
53
53
235
332
1093
1083
46
47
288
395
1056
1048
66
67
273
379
1188
1170
59
60
325
437
1320
1292
53
54
381
496
1519
1474
46
48
522
529