MODEL
TYPE
RATINGS 2
40% (low) heat Input BTUH
40% (low) heat Capacity BTUH (ICS) 36
100% (high) heat Input BTUH
100% (high) heat Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
AFUE
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
FLA
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT Size Min. (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size 5
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5 Furnace ships in natural gas configuration. The LP conversion kit used with the modulating furnace is BAYLPSS220B or BAYLPKT220B.
6 45% (low) heat for *UHM1D120ACV5VB.
7 Energy Star
8 Check motor nameplate for actual FLA
General
Data
TUHM PRODUCT SPECIFICATIONS1

TUHMB060ACV3VB 7

Upflow/ Horizontal Left
24,000
23,352
60,000
58,380
35 - 65
97.3
DIRECT
10 x 8
1
Variable
See Fan Performance Table
See Fan Performance Table
1/2
Variable
115/1/60
5.2 - 6.2 8
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Three Stage
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
8.8
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 146

TUHMB080ACV3VB 7

Upflow/ Horizontal Left
Upflow/ Horizontal Left
32,000
30,944
80,000
77,360
35 - 65
96.7
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
5.2 - 6.2 8
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
8.8
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 156
6

TUHMC100ACV4VB

TUHMD120ACV5VB 7

Upflow/ Horizontal Left
40,000
38,400
100,000
96,000
35 - 65
96.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
7.4
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
1 - 20x25 - 1 in.
2.5 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Three Stage
Hot Surface Igniter
Hot Surface Igniter
Multiport Inshot
5
115/1/60
10.4
15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
41-3/4 x 26-1/2 x 30-1/2
197 / 185
54,000
52,380
120,000
116,400
40 - 70
97.0
DIRECT
10 x 10
1
Variable
1
Variable
115/1/60
9.9
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Yes
High Velocity
1 - 24x25 - 1 in.
3 Round
20
6 — 45
6 — 56
Multiport Inshot
6
115/1/60
13.5
15
1/2
H x W x D
206 / 193
Pub. No. 22-1840-14