Specification Vitotronic 200, Type Ho1B; Solar Control Module, Type Sm1; Vitotronic 200 Rf, Type Ho1C, For Weather-Compensated Operation - Viessmann VITODENS 242-F Technical Manual

Gas condensing storage combi boiler
Table of Contents

Advertisement

Control units
(cont.)

Specification Vitotronic 200, type HO1B

Rated voltage
Rated frequency
Rated current
Safety category
Permissible ambient
temperature
– During operation
– During storage and
transport
Electronic temperature
limiter setting (heating
mode)

Solar control module, type SM1

Included in the standard delivery of the Vitodens 242-F.
Assembly
The solar control module contains:
■ PCB
■ Connection terminals for:
– 2 sensors
– Solar circuit pump
– KM BUS
– Power supply (on-site ON/OFF switch)
■ PWM output for controlling the solar circuit pump
The standard delivery includes collector temperature sensor and cyl-
inder temperature sensor.
Collector temperature sensor
For connection inside the appliance.
On-site extension of the connecting lead:
■ 2-core lead, length up to 60 m with a cross-section of 1.5 mm
per)
■ Never route this lead immediately next to 230/400 V cables
Lead length
IP rating
Sensor type
Permissible ambient temperature
– During operation
– During storage and transport
Cylinder temperature sensor
Installed in the Vitodens and connected.
7
IP rating
Sensor type

7.3 Vitotronic 200 RF, type HO1C, for weather-compensated operation

In conjunction with Vitodens 333-F and 343-F
Design and functions
Modular design
The control unit is integrated into the boiler.
The control unit comprises a standard unit, electronics modules and a
programming unit.
VIESMANN
84
230 V~
50 Hz
6 A
I
0 to +40 °C
Installation in living spaces or boiler rooms
(standard ambient conditions)
–20 to +65 °C
82 °C (change not possible)
2.5 m
IP 32 to EN 60529, ensure
through assembly/installa-
tion
Viessmann NTC 20 kΩ at
25 °C
−20 to +200 °C
−20 to +70 °C
IP 32 to EN 60529, ensure
through assembly/installa-
tion
Viessmann NTC 10 kΩ at
25 °C
DHW temperature set-
ting range
– Vitodens with loading
cylinder
– Vitodens with DHW
cylinder with internal
indirect coil
Heating curve setting
range
Slope
Level
Permissible ambient temperature
– During operation
– During storage and transport
Functions
■ Switching the solar circuit pump
■ Electronic limiter for the temperature in the DHW cylinder (safety
shutdown at 90 °C)
■ Collector safety shutdown
■ Solar circuit pump speed control via wave packet control or solar
circuit pump with PWM input (Grundfos)
■ Suppression of DHW cylinder reheating by the boiler (auxiliary func-
tion for DHW heating is possible)
■ Output statement and diagnostic system
Specification
Rated voltage
Rated frequency
2
Rated current
(cop-
Power consumption
Safety category
IP rating
Function
Permiss. ambient temperature
– During operation
– During storage and transport
Rated relay output breaking capaci-
ty
– Semi-conductor relay 1
– Total
Standard unit:
■ ON/OFF switch
■ LON communication module
For example, for remote control of the heating system by the Vitotrol
app (iOS 6.0 and Android 4.0 operating system) in conjunction with
Vitocom 100 LAN1.
10 to 63 °C
10 to 68 °C
0.2 to 3.5
–13 to 40 K
0 to +90 °C
−20 to +70 °C
230 V ~
50 Hz
2 A
1.5 W
II
IP 20 to EN 60529; ensure
through assembly/installation
Type 1 B to EN 60730-1
0 to +40 °C for use in the living
space or boiler room (standard
ambient conditions)
−20 to +65 °C
1 (1) A, 230 V~
max. 2 A