Vitodens 242-F, type B2UA

3.2 Specification

Gas boiler, type B and C, category II
Rated heating output range (to EN 677)
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
Rated heating output for DHW heating
Rated heat input
Product ID
IP rating
Gas supply pressure
Natural gas
LPG
Max. permissible gas supply pressure
Natural gas
LPG
3
Sound power level
(to EN ISO 15036-1)
at partial load
at rated heating output (DHW heating)
Power consumption
– in delivered condition
– Max.
Weight
– Total (with casing)
– Heat cell module
– Cylinder module
Heat exchanger content
Content, solar circuit
Max. flow rate
(Limit for the use of hydraulic separation)
Nominal circulation water volume
at T
/T
= 80/60 °C
F
R
Expansion vessel
Contents
Pre-charge pressure
Permiss. operating pressure
– Heating circuit
– Solar circuit
Connections (with connection accessories)
Boiler flow and return
Solar flow and return
Cold water and DHW
DHW circulation
Dimensions
Length
Width
Height
Height when tilted
Gas connection (with connection accessories)
DHW cylinder
Contents
Permiss. operating pressure (DHW side)
Continuous DHW output
when heating DHW from 10 to 45 °C
Performance factor N
*7
L
*6
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor upstream of the system.
*7
At 70 °C average boiler water temperature and cylinder storage temperature Tcyl = 60 °C.
The DHW performance factor NL depends on the cylinder storage temperature Tcyl.
Standard values: Tcyl = 60 °C → 1.0 × NL Tcyl = 55 °C → 0.75 × NL Tcyl = 50 °C → 0.55 × NL Tcyl = 45 °C → 0.3 × NL.
VIESMANN
20
(cont.)
2N3P
kW
kW
kW
kW
mbar
kPa
mbar
kPa
*6
mbar
kPa
mbar
kPa
dB(A)
dB(A)
W
W
kg
kg
kg
litres
litres
litres/h
litres/h
litres
bar
kPa
bar
MPa
bar
MPa
R
R/Ø mm
R
R
mm
mm
mm
mm
R
litres
bar
MPa
kW
litres/h
Values in ( ) when operating with LPG P
3.2 (4.8) - 13.0
3.2 (4.8) - 19.0
2.9 (4.3) - 11.8
2.9 (4.3) - 17.2
2.9 (4.3) - 17.2
2.9 (4.3) - 17.2
3.1 (4.5) - 17.9
3.1 (4.5) - 17.9
CE-0085CN0050
IP X4D to EN 60529
20
2
50
5
25.0
2.5
57.5
5.75
33
37
39
157
161
42
95
1.8
9.9
1200
507
12
0.75
75
3
0.3
6
0.6
¾
¾/22
½
½
595
600
1875
2000
½
170
10
1
17.2
422
1.4
5.2 (8.8) - 26.0
4.7 (8.0) - 23.7
4.7 (8.0) - 29.3
4.9 (8.3) - 30.5
20
20
2
2
50
50
5
5
25.0
25.0
2.5
2.5
57.5
57.5
5.75
5.75
33
35
40
43
53
68
160
209
161
165
42
46
95
95
1.8
2.4
9.9
9.9
1200
1400
739
1018
12
12
0.75
0.75
75
75
3
3
0.3
0.3
6
6
0.6
0.6
¾
¾
¾/22
¾/22
½
½
½
½
595
595
600
600
1875
1875
2000
2000
½
½
170
170
10
10
1
1
17.2
29.3
422
719
1.4
2.0
VITODENS