Installation Vitodens 242-F - Viessmann VITODENS 242-F Technical Manual

Gas condensing storage combi boiler
Table of Contents

Advertisement

Design information

Installation Vitodens 242-F

Connection sets for installation on finished walls, for upward
connection
Connection set without pre-mounting bracket, part no. 7348 552
440
330
220
55
A
B
C
D
E F
G
A
B
C
D
E F
G
6
A Solar return R ¾/Ø 22 mm
B Heating flow R ¾
C DHW R ½
D DHW circulation R ½ (separate accessory)
Type
Vitodens 242-F, B2UA
Note
The adjustable feet give the height measurements of the connections
a tolerance of + 15 mm.
For connecting on-site lines on the gas, heating water and DHW sides
from above.
VIESMANN
58
(cont.)
H
H
a
mm
1927
Connection set with pre-mounting bracket for pre-installation in
unfinished buildings, part no. 7351 778
440
330
220
55
A
B
C
D
E F
A
B
C
E F
D
E Gas connection R ½
F Cold water R ½
G Heating return R ¾
H Solar flow R ¾/Ø 22 mm
b
c
mm
mm
mm
1964
1976
1890
Connection set comprising:
■ Connection panel (only for part no. 7351 778)
■ Connection pipes
■ Shut-off valves for heating water flow and return, with boiler drain &
fill valve
■ 2 connectors for DHW
■ 2 connectors each for solar flow and return (R¾/Ø 22 mm)
■ Gas shut-off valve with thermally activated safety shut-off valve
G
H
G
H
d
e
f
mm
mm
1940
2011
g
mm
2023
VITODENS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 333-fVitodens 222-f

Table of Contents