Electrical Adjustments; Service Adjustment Menu Operation; Memory Ic (Ic1371) Replacement - Sanyo PLC-XE40 Service Manual

Hide thumbs Also See for PLC-XE40:
Table of Contents

Advertisement

Electrical Adjustments

Service Adjustment Menu Operation

To enter the service mode
To enter the "Service Mode", press and hold the MENU button on the remote control for more than 20 seconds.
The service menu appears on the screen as follows.
To adjust service data
Select the adjustment group no. by pressing the MENU button (increase) or KEYSTONE button (decrease), and
select the adjustment item no. by pressing the pointer e or d button on the remote control, and change the data
value by pressing the 7 or 8 button on the remote control. Refer to the "Service Adjustment Data Table" for fur-
ther description of adjustment group no., item no. and data value.
To exit the service mode
To exit the service mode, press the ON-OFF button on the remote control.
Service Mode
Input
Video
Group
No.
0
0
Ver.
1
Item No.
Group No.

Memory IC (IC1371) Replacement

Memory IC on the main board stores the data for
the service adjustments, and should not be replaced
except for the case of defective device.
If replaced, the re-adjustments are required following
to the "Electrical Adjustments".
The data of lamp replacement counter is stored in the
Memory IC.
Please note that the lamp replace counter will be
reset when the memory IC is replaced.
(Lamp replace counter cannot be set to the previous
value.)
● Caution to memory IC replacement
When memory IC is replaced with new one, the CPU
writes down the default data of the service adjust-
ments to the replaced IC as the mentioned on the ser-
vice adjustment table. As these data are not the same
Data
32
.00
Data value
data as factory shipped data, it should be required to
perform the re-adjustments following to the "Electrical
Adjustments".
Please note that in this case the lamp replace counter
will be reset.
● Caution of Main Board replacement (in the case
memory IC is not defective)
When the main board is replaced, memory IC should
be replaced with the one on previous main board.
After replacement, it should be required to per-
form the re-adjustments following to the "Electrical
Adjustments".
In this case, the lamp replace counter can be kept the
value as before.
-24-