4. Disassembly and Reassembly

4-1 Removal of Outer Panel
1. Remove five screws from the rear section.
2. Lift the outer panel by pulling it backwards
4-2 Replacement of Magnetron and Fan Motor
1.
The magnetron includes the shield case,
permanent magnet, check coils and 500pF
capacitors (all contained in one assembly).
2.
Discharge the high voltage capacitor.
(See page1-2)
3.
Disconnect all lead wires from the magnetron.
4.
Remove screw(1) securing the magnetron
supporter.
5.
Remove the magnetron supporter.
6.
Remove the air cover
7.
Remove screw(1) securing the assy thermal
cutout switch.
8.
Remove screws securing the magnetron to the
wave guide.
9.
Remove the magnetron very carefully.
10. Remove screws from the back panel to take
out fan motor.
11. When removing the magnetron, make sure
that its antenna does not hit any adjacent
parts.
12. When replacing the magnetron, be sure to
remount the magnetron gasket in the correct
position, and make sure the gasket is in good
condition.
Samsung Electronics
SCREW
Cover Air
Screw(1)
Screw(1)
Magnetron Fan Motor
4-1