10. Service technicians should remove their 16. Always connect a test instrument's ground watches while repairing an MWO. lead to the instrument chassis ground before connecting the positive lead; always remove the instrument's ground lead last. Samsung Electronics...
Page 3
PRECAUTION DO NOT measure the voltage in the high voltage circuit Servicemen should remove their watches whenever including filament voltage of magnetron. working close to or replacing the magnetron. Samsung Electronics...
4) Check microwave leakage after repair work is carried out on magnetron. 4-3 Replacement of Lamp screws of lamp 1) Remove out panel. 2) Remove two screws securing lamp holder. Thermistor Probe Thermal Cutout Switch Samsung Electronics...
Page 7
4. Remove screws 1) securing convection heater Ass'y. 5. Remove nut'2', blade fan'3', spring washer'4' and bushing'5'. 6. Remove convection assembly '11', '12' and cooling fan'10'. 7. Remove four screws '6'. 8. Remove heater cover '7' '9'. Then heater adiabatic '8' will be disassembled. Samsung Electronics...
Page 8
K E N K E N TI M IS H 18 .F P IE /W E IG H 19 .F V E G ZE N E TA V E G B LE E TA B LE S TA Samsung Electronics...
Page 9
2. Disconnect the connectors from the control circuit board. 3. Remove screws securing the control circuit bord. 4. Lift up the control circuit board from right side and remove the hooks holding the contol circuit board to the box assembly. Screws Screws Samsung Electronics...
1. Isolate the magnetron from the circuit by disconnecting its leads. 2. A continuity check across the magnetron filament terminals should indicate one ohm or less. 3. A continuity check between each filament terminal and magnetron case should read open. Cooling Fins Samsung Electronics...
0.5mm when Lever Slider B door is closed. Door Open Door Closed (Door Close Condition) (Door Open Condition) ∞ Primary switch ∞ Monitor switch (COM-NC) ∞ Monitor switch (COM-NO) ∞ Door Sensing S/W Samsung Electronics...
Page 12
5. After heating for 2 minutes, measure the water temperature in each beaker. 6. Microwave heat distribution rate can be calculated as follows: Minimum Beaker Temperature Rise Heat Distribution = X 100(%) Maximum Temperature Rise The result should exceed 65%. Cooking Tray Samsung Electronics...
Hold the probe LÖSCHEN START perpendicular to the cabinet door. Place the spacer CE124CF cone of the probe on the door and/or cabinet door seam and move along the seam, the door viewing window and the exhaust openings moving the probe in a clockwise direction at a rate of 1 inch/sec.
H.V.Transformer component test procedure and replace if it is H.V.Capacitor defective. H.V.Diode,H.V.Fuse Magnetron 4. Open or loose wiring of power relay 5. Defective primary latch switch 6. Defective power relay or Ass'y PCB Replace PCB main. Samsung Electronics...
Page 15
Use plastic wrap or cover with a lid. Stir once or twice while cooking foods such as soup, cocoa, or milk. Noise from the turntable motor Noise may result from the motor. Replace turntable motor. when it starts to operate. Samsung Electronics...
ITEM OPEN CLOSE WAVE -TION GRILL CONV. CONV. PRI.S/W OPEN CLOSE CLOSE CLOSE CLOSE CLOSE CLOSE CLOSE MON.S/W CLOSE OPEN OPEN OPEN OPEN OPEN OPEN OPEN MAIN RY SEC.S/W RY GRILL RY CONV. HEA.RY FAN.MTR.RY DAMPER RY CONV.MTR.RY Samsung Electronics...
(YEL) SECONDARY (BLU,RED) :W-H-A=BLU , W-H-B=RED ORG BLK VOLTAGE (RED) CON 1 PRIMARY SWITCH DOOR SENSING SWITCH MONITOR SWITCH MAGNETRON HIGH VOLTAGE DIODE TO CHASSIS HIGH VOLTAGE CAPACITOR H.V.FUSE SYMBOL COLOR ORANGE WHITE BLACK YELLOW HIGH VOLTAGE TRANSFORMER Samsung Electronics...