TECHNICAL
TECHNICAL
GUIDE
GUIDE
MODELS: GM9S*DH
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW/HORIZONTAL FURNACES
92% TO 94% AFUE
NATURAL GAS
40 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
ISO 9001
Certified Quality
Management System
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
Integrated control module for reliable, economical opera-
tion.
May be installed as either two-pipe (sealed combustion)
or single pipe vent (using indoor combustion air)
Top intake & vent connection allows downflow installa-
tion in narrow locations.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
No special vent termination kit required.
100% shut off main gas valve for extra safety.
PSC four speed, direct drive motor with large, quiet
blower.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
Timed on, adjustable off blower capability for maximum
comfort.
Easy access from front of unit for cleaning, maintenance
or service.
Protection from intake, exhaust or condensate blockage.
278177-BTG-A-0407

Advertisement

Table of Contents
loading

Summary of Contents for York GM9S040A12DH11

  • Page 1 Protection from intake, exhaust or condensate blockage. Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.gamanet.org.
  • Page 2: Cabinet And Duct Dimensions

    23-1/4 BOTTOM IMAGE TOP IMAGE SUPPLY END RETURN END CABINET AND DUCT DIMENSIONS Cabinet Dimension Cabinet Models Size A (in.) B (in.) C (in.) D (in.) GM9S040A12DH11 1200 14-1/2 13-1/4 1-3/4 GM9S060B12DH11 1200 17-1/2 16-1/4 1-3/4 GM9S080B12DH11 1200 17-1/2 16-1/4...
  • Page 3: Electrical And Performance Data

    ELECTRICAL AND PERFORMANCE DATA Input/ Nominal Cabinet Air Temp. Output Total Unit AFUE Cabinet Airflow Width Rise Models Amps °F GM9S040A12DH11 40/A 1200 14-1/2 35 - 65 GM9S060B12DH11 60/B 1200 17-1/2 35 - 65 GM9S080B12DH11 80/B 1200 17-1/2 35 - 65...
  • Page 4: Blower Performance Cfm

    High 1635 1590 1535 1480 1415 1340 1280 1185 Medium High 1179 1170 1160 1140 1135 1098 1048 1026 GM9S040A12DH11 Medium Low High 1687 1652 1631 1595 1557 1511 1456 1382 1313 1211 Medium High 1193 1183 1173 1162 1142...
  • Page 5: Recommended Filter Sizes

    278177-BTG-A-0407 FILTER PERFORMANCE RECOMMENDED FILTER SIZES The airflow capacity data published in the “Blower Perfor- Cabinet Size Top Return Filter in mance” table listed above represents blower performance 1200 (2) 14 x 20 WITHOUT filters. To determine the approximate blower per- 1200 (2) 14 x 20 formance of the system, apply the filter drop value for the fil-...
  • Page 6 278177-BTG-A-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. Thermostat Chart Unitary Products Group...
  • Page 7: Applying Filter Pressure Drop To Determine System Airflow

    278177-BTG-A-0407 APPLYING FILTER PRESSURE DROP TO ACCESSORIES DETERMINE SYSTEM AIRFLOW PROPANE (LP) CONVERSION KIT - To determine the approximate airflow of the unit with a filter in 1NP0347 - All units place, follow the steps below: This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation.
  • Page 8 NOTES Subject to change without notice. Printed in U.S.A. 278177-BTG-A-0407 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 246730/036-21561-003 Rev. A (1205) Unitary 5005 Norman Products York Group Drive 73069...

This manual is also suitable for:

Gm9s060b12dh11Gm9s080b12dh11Gm9s080c16dh11Gm9s100c16dh11Gm9s100c20dh11Gm9s120d20dh11

Table of Contents