York GY9F*DH series Technical Manual

Gas-fired condensing / high efficiency downflow/horizontal furnace

Advertisement

Quick Links

TECHNICAL GUIDE
MODELS: GY9F*DH
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW/HORIZONTAL FURNACES
95% AFUE
NATURAL GAS
64 - 80 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
ISO 9001
Certified Quality
Management System
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
Integrated control module for reliable, economical opera-
tion.
May be installed as either two-pipe (sealed combustion)
or single pipe vent (using indoor combustion air)
Top intake & vent connection allows downflow installa-
tion in narrow locations.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
No special vent termination kit required.
100% shut off main gas valve for extra safety.
PSC four speed, direct drive motor with large, quiet
blower.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
Timed on, adjustable off blower capability for maximum
comfort.
Easy access from front of unit for cleaning, maintenance
or service.
Protection from intake, exhaust or condensate blockage.
339033-YTG-A-0607

Advertisement

Table of Contents
loading

Summary of Contents for York GY9F*DH series

  • Page 1 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.gamanet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2: Cabinet And Duct Dimensions

    339033-YTG-A-0607 T-STAT WIRING 7/8” K.O. T-STAT WIRING 7/8” K.O. HORIZONTAL CONDENSATE HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” DRAIN OPENING 1-3/4” HORIZONTAL CONDENSATE HORIZONTAL DRAIN OPENING 2” CONDENSATE DRAIN OPENING 1-3/4” JUNCTION BOX HOLE 7/8” JUNCTION BOX HOLE 7/8” GAS PIPE ENTRY 1-1/2” GAS PIPE CONDENSATE DRAIN ENTRY 1-1/2”...
  • Page 3: Blower Performance Cfm

    339033-YTG-A-0607 BLOWER PERFORMANCE CFM AIRFLOW WITH TOP RETURN - WITHOUT FILTERS (CFM) External Static Pressure, Inches W.C. Speed Models High 2071 2026 1981 1935 1864 1796 1713 1625 1532 1401 Medium High 1583 1590 1569 1554 1532 1502 1457 1409 1327 1221 GY9F064C16DH11...
  • Page 4 339033-YTG-A-0607 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalogue Section. Thermostat Chart Unitary Products Group...
  • Page 5: Applying Filter Pressure Drop To Determine System Airflow

    339033-YTG-A-0607 APPLYING FILTER PRESSURE DROP TO ACCESSORIES DETERMINE SYSTEM AIRFLOW PROPANE (LP) CONVERSION KIT - To determine the approximate airflow of the unit with a filter in 1NP0357 - All Models place, follow the steps below: This accessory conversion kit may be used to convert natural Select the filter type.
  • Page 6 339033-YTG-A-0607 NOTES Unitary Products Group...
  • Page 7 339033-YTG-A-0607 Unitary Products Group...
  • Page 8 Subject to change without notice. Printed in U.S.A. 339033-YTG-A-0607 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Products York Group Drive 73069...

Table of Contents