TECHNICAL GUIDE
MODELS: GY8S*UH / LY8S*UH
GAS-FIRED
HIGH EFFICIENCY SINGLE STAGE
UPFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx
NATURAL GAS
40 - 130 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement, specifica-
tions are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
aluminized tubular heat exchangers. The units are factory
shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel
Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
ISO 9001
Certified Quality
Management System
Easily applied in upflow, horizontal left or horizontal right
installation with no conversion necessary.
100% shut off main gas valve for added safety.
Rollout safety control.
Low unit amp requirement for easy application.
High quality inducer motor for quiet operation.
Built-in self diagnostics with fault code display.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Standard terminals for controlling humidifiers and EAC's.
40 VA control transformer fuse protected.
Easy to connect power and control wiring.
Efficiency ratings of 80 AFUE attained by using tubular
heat exchangers.
Cooling relay supplied for easy installation of add-on
cooling.
Multi-speed PSC, large, quiet direct-drive blower motor
to match cooling requirements.
Adjustable fan-off settings to eliminate "cold-blow".
Compact 40-in height allows installation in small space
confines.
Low NOx models have been designed to meet specific
code requirements.
All models are propane convertible.
278436-YTG-A-0407

Advertisement

Table of Contents
loading

Summary of Contents for York GY8S*UH

  • Page 1 RATING CERTIFIED Due to continuous product improvement, specifica- tions are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional information can be found at www.gamanet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2: Cabinet And Duct Dimensions

    278436-YTG-A-0407 FRONT CABINET AND DUCT DIMENSIONS Models (G,L)Y8S040A12UH11 1200 (G,L)Y8S060A12UH11 1200 (G,L)Y8S080A12UH11 1200 (G,L)Y8S080B16UH11 1600 (G,L)Y8S080C16UH11 1600 GY8S080C22UH11 2200 LY8S080C20UH11 2000 (G,L)Y8S100B12UH11 1200 (G,L)Y8S100B16UH11 1600 (G,L)Y8S100C16UH11 1600 (G,L)Y8S100C20UH11 2000 GY8S115C16UH11 1600 (G,L)Y8S115C20UH11 2000 (G,L)Y8S130D20UH11 2000 (VENT CONNECTIONS) POWER WIRING 7/8” HOLE 13-3/4 2-1/2 GAS INLET...
  • Page 3: Ratings & Physical / Electrical Data - Upflow Models

    RATINGS & PHYSICAL / ELECTRICAL DATA - UPFLOW MODELS Input Models (G,L)Y8S040A12UH11 (G,L)Y8S060A12UH11 (G,L)Y8S080A12UH11 (G,L)Y8S080B16UH11 (G,L)Y8S080C16UH11 GY8S080C22UH11 LY8S080C20UH11 (G,L)Y8S100B12UH11 (G,L)Y8S100B16UH11 (G,L)Y8S100C16UH11 (G,L)Y8S100C20UH11 GY8S115C16UH11 (G,L)Y8S115C20UH11 (G,L)Y8S130D20UH11 Input Models (G,L)Y8S040A12UH11 (G,L)Y8S060A12UH11 (G,L)Y8S080A12UH11 (G,L)Y8S080B16UH11 (G,L)Y8S080C16UH11 GY8S080C22UH11 LY8S080C20UH11 (G,L)Y8S100B12UH11 (G,L)Y8S100B16UH11 (G,L)Y8S100C16UH11 (G,L)Y8S100C20UH11 GY8S115C16UH11 (G,L)Y8S115C20UH11 (G,L)Y8S130D20UH11 Nominal external static pressure is 0.50”...
  • Page 4 278436-YTG-A-0407 BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - BOTTOM RETURN Models Speed High Medium High (G,L)Y8S040A12UH11 Medium Low High Medium High (G,L)Y8S060A12UH11 Medium Low High Medium High (G,L)Y8S080A12UH11 Medium Low High (G,L)Y8S080B16UH11 Medium High (G,L)Y8S080C16UH11 Medium High Medium High GY8S080C22UH11 LY8S080C20UH11 Medium Low...
  • Page 5 BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - LEFT SIDE RETURN Models Speed High Medium High (G,L)Y8S040A12UH11 Medium Low High Medium High (G,L)Y8S060A12UH11 Medium Low High Medium High (G,L)Y8S080A12UH11 Medium Low High (G,L)Y8S080B16UH11 Medium High (G,L)Y8S080C16UH11 Medium High Medium High GY8S080C22UH11 LY8S080C20UH11 Medium Low...
  • Page 6: Horizontal Sidewall Venting

    278436-YTG-A-0407 HORIZONTAL SIDEWALL VENTING For applications where vertical venting is not possible, the only approved method of horizontal venting is the use of an auxiliary power vent. Approved power venters are Fields Controls Model SWG-4Y or Tjernlund Model GPAK-JT. Fol- low all application and installation details provided by the manufacturer of the power vent.
  • Page 7 278436-YTG-A-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. Thermostat Chart Unitary Products Group...
  • Page 8: Applying Filter Pressure Drop To Determine System Airflow

    Subtract airflow reduction value to airflow @ 0.50 w.c. (125 Pa) to obtain actual airflow @ 0.58 in. w.c. (144 Pa) ESP. 1250 - 56 = 1194 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2007. All rights reserved. Unitary Products Group...