Split type, heat pump
built-in duct type
ceiling type
wall type
carcase type
low wall/painted floor type
2 way cassette type
4 way cassette type (120 pages)
Heronhill - for all your Toshiba requirements CONTENTS IMPORTANT NOTES ........................3 SPECIFICATIONS ..........................4 CONSTRUCTION VIEWS ......................... 7 WIRING DIAGRAM .......................... 8 SPECIFICATIONS OF ELECTRICAL PARTS ..................9 REFRIGERANT PIPING DIAGRAM ....................10 PERFORMANCE CHARACTERISTICS ................... 11 EXPLODED VIEWS AND PARTS LISTS ..................13 SUMMARY •...
Heronhill - for all your Toshiba requirements 1. IMPORTANT NOTES Refer to Service Manual, File No. A90-9504 for details of indoor units and control circuits. Reverse Phase Protector The Scroll Compressor used in this unit can only rotate in one direction. For this reason a protective device ( Reverse Phase Protector ) is fitted to prevent incorrect wiring of electrical phases.
Heronhill - for all your Toshiba requirements 2. SPECIFICATIONS MODEL RAV-362B-PE RAV-462B-PE ITEM Cooling capacity 10.0 12.5 Phase Power source 380 – 415 380 – 415 COOLING COOLING Power consumption Power Factor Running current Starting current Indoor unit dB(A) 45/42/39 46/43/40 (High/Med./Low)
Page 5
Heronhill - for all your Toshiba requirements MODEL RAV-362C-PE RAV-462C-PE ITEM Cooling capacity 10.0 12.5 Phase Power source 380 – 415 380 – 415 COOLING COOLING Power consumption Power Factor Running current Starting current Indoor unit dB(A) 47/43/40 49/45/41 (High/Med./Low)
Page 6
Heronhill - for all your Toshiba requirements MODEL RAV-362U-PE RAV-462U-PE ITEM Cooling capacity 10.0 12.5 Phase Power source 380 – 415 380 – 415 COOLING COOLING Power consumption Power Factor Running current Starting current Indoor unit dB(A) 50/45/42 52/47/44 (High/Med./Low)
Heronhill - for all your Toshiba requirements 3. CONSTRUCTION VIEWS RAV-363A8-PE RAV-463A8-PE Space required for service (Space for wiring and piping) Outlet (Space for wiring and piping) When installed with the inlet When installed with the outlet faced to the wall side...
Heronhill - for all your Toshiba requirements 4. WIRING DIAGRAM Indoor Unit Outdoor Unit Earth Surge Absorber Screw Power Supply shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Compressor has internal thermal protection. Do not operate the units with the magnetic contactor pushed in.
Heronhill - for all your Toshiba requirements 5. SPECIFICATIONS OF ELECTRICAL PARTS RAV-363A8-PE Parts Name Type Specifications Output (Rated) 3.0kW, 2 pole, 3 phase, 380/415V, 50 Hz Compressor ZR49K3-TFD Winding resistance 3.73 Ω , at 20 °C SMF-230-63N-3 Output (Rated) 63W, 6 pole,1 phase, 230V, 50 Hz...
Page 12
Heronhill - for all your Toshiba requirements 7.3 Piping length/additional refrigerant volume Additional amount of refrigerant Piping length Recharge quantity (kg) at installation site (kg) less than (m) Model Filled at RAV-463A8-PE factory 0.25 0.75 1.25 3.45 3.55 3.95 4.45 4.95...