Page 12
8.
Check all refrigerant lines and conduit
lines to guard against vibrations and possible
failure.
9.
Is the unit in a room where ambient
temperatures are within a minimum of 10°C
(50¯F) even in winter months?
10. Is there at least a 15 cm (6") clearance
WARNING. This icemaker is not designed for outdoor installation and will not function
in ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above
40°C (100°F).
around the unit for proper air circulation?
11. Has the water supply pressure been
checked to ensure a water pressure of at least 1
bar (14 psi).
12. Has the owner been given the name and the
phone number of the authorized SCOTSMAN
Service Agency serving him?
G. INSTALLATION PRACTICE
1. Hand shut-off valve
2. Water filter
3. Water supply line (flexible hose)
4. 3/4" male fitting
5. Vented drain
6. Open trapped vented drain
7. Drain fitting
8. Main switch
9. Power line