Installation Practice - Scotsman ACM 85 Service Manual

Electronic cubers with storage
Table of Contents

Advertisement

Page 12
8.
Check all refrigerant lines and conduit
lines to guard against vibrations and possible
failure.
9.
Is the unit in a room where ambient
temperatures are within a minimum of 10°C
(50¯F) even in winter months?
10. Is there at least a 15 cm (6") clearance
WARNING. This icemaker is not designed for outdoor installation and will not function
in ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above
40°C (100°F).
around the unit for proper air circulation?
11. Has the water supply pressure been
checked to ensure a water pressure of at least 1
bar (14 psi).
12. Has the owner been given the name and the
phone number of the authorized SCOTSMAN
Service Agency serving him?
G. INSTALLATION PRACTICE
1. Hand shut-off valve
2. Water filter
3. Water supply line (flexible hose)
4. 3/4" male fitting
5. Vented drain
6. Open trapped vented drain
7. Drain fitting
8. Main switch
9. Power line