Design information
Connection set with pre-mounting bracket for pre-assembly on finished walls in unfinished buildings, part no. 7354 669
440
330
220
55
50
A
B
C
D
E F
G
H
A
B
C
D
E F
G
H
6
A Solar return R ¾
B Heating flow R ¾
C DHW R ½
D DHW circulation R ½ (separate accessory)
E Gas connection R ½
Type
Vitodens 242-F, FB2B
A wall clearance of 70 mm is required behind the Vitodens.
Note
The adjustable feet give the height measurements of the connections
a tolerance of + 15 mm.
VIESMANN
62
(cont.)
K
70
a
b
mm
mm
1913
1925
F Cold water R ½
G Heating return R ¾
H Solar flow (R ¾)
K Balanced flue connection towards the back
c
For connecting on-site lines on the gas, heating water and DHW sides
from below.
mm
2102
Connection set comprising:
■ Connection panel
■ Connecting pipes
■ Shut-off valves for heating water flow and return with boiler drain &
fill valve and air vent valve
■ 2 connectors for DHW
■ 2 connectors for solar flow and return
■ Gas angle valve with thermally activated safety shut-off valve
VITODENS