Design information
Note
The adjustable feet give the height measurements of the connections
a tolerance of + 15 mm.
For connecting on-site lines on the gas, heating water and DHW sides
from the left or right.
Connection set with premounting bracket for pre-assembly in unfinished buildings, part no. 7354 403
452
440
370
316
F
E
D
C
B
A
6
A Heating flow R ¾
B DHW R ½
C DHW circulation R ½ (separate accessory)
D Gas connection R ½
Type
Vitodens 222-F, FS2B
- 19 and 26 kW
- 35 kW
Vitodens 333-F, FS3B
Vitodens 333-F, FR3B
VIESMANN
52
(cont.)
50
G
A
B
C
D
E
F
a
b
mm
mm
mm
1402
972
1027
1602
1172
1227
1402
972
1027
1602
1172
1227
Connection set comprising:
■ Connecting pipes
■ Shut-off valves for heating water flow and return with boiler drain &
fill valve
■ 2 connectors for DHW
■ Gas shut-off valve with thermally activated safety shut-off valve
E Cold water R ½
F Heating return R ¾
G Balanced flue connection (towards the back)
c
d
e
mm
mm
mm
1082
1137
1192
1282
1337
1392
1082
1137
1192
1282
1337
1392
f
g
h
mm
mm
mm
1247
1302
1552
1447
1502
1752
1247
1302
1582
1447
1502
1782