Vitodens 333-F, type FS3B
Variable speed heating circuit pump in the Vitodens 333-F
The integral circulation pump is a highly efficient DC pump with sub-
stantially lower power consumption than conventional pumps.
The pump speed and consequently the pump rate is regulated subject
to the outside temperature and the switching times for heating or
reduced mode. The control unit transmits the current default speed via
an internal data BUS to the circulation pump.
Individually match the minimum and maximum speed plus the speed
for reduced mode to the existing heating system using the control unit
codes.
In the delivered condition, the minimum pump rate (coding address
"E7") is set to 30 %. The maximum pump rate (coding address "E6")
is set to the following values:
Rated output range in kW
3.8-13
3.8-19
5.2-26
Residual head of the integral circulation pump
Vitodens 333-F, 3.8-19 kW
40
400
350
30
300
250
20
200
150
10
100
50
0
0
0
100
200
Flow rate in l/h
E Upper operational limit
Curve
Circulation pump rate
A
30 %
B
50 %
C
75 %
D
100 %
VITODENS
(cont.)
Speed settings in the
delivered condition in %
50
55
65
300
400
500
600
700
Setting code address "E6"
E6:030
E6:050
E6:075
E6:100
Circulation pump VI UPM-15-70 KM
Rated voltage
Power consumption
max.
min.
Power consumption in
the delivered condition
– 13 kW
– 19 kW
– 26 kW
B
A
800
900
1000
1100
V~
230
W
70
W
6
W
24
W
27
W
37
E
D
C
1200
1300
1400
VIESMANN
25
3