4 Configuration
System > Time Profile
The Time Profile page allows users to configure the time profile settings of the device.
Range Name: Specifies the profile name.
Date: Select Date and specifies the From Day and To Day of the time profile.
Time(HH MM): Specifies the Start Time and End Time.
Weekdays: Specifies the work day.
Click Add to create a new time profile or click Delete to delete a time profile from the table.
System > Power Saving
The Power Saving mode feature reduces power consumption automatically when the RJ-45 port is link down
or the connected devices are turned off. Less power will be consumed also when the short cable is used
(less than 20 meters).
By reducing power consumption, less heat is produced, resulting in extended product life and lower
operating costs. By default, the Cable Length Detection and Link Status Detection are enabled. Click Apply
to make the change effective.
Advanced Power Saving Settings:
Type: Specifies the Power Saving type to be LED Shut-off, Port Shut-off, Port Standby or System
Hibernation.
LED Shut-off - The LED Shut-off gets high priority. If the user select LED Shut-off, the profile
function will not take effect. It means the LED can not be turned on after Time Profile time's up when
the state is disabled. On the contrary, if the LED is enabled, the Time Profile function will work.
DGS-1210 series Metro Ethernet Managed Switch User Manual
Figure 4.42 – System > Time Profile Settings
NOTE: The time must be set after current time,
otherwise it will take effect on the next cycle time.
Figure 4.43 – System > Power Saving