Sanyo PLC-WXE46A Service Manual page 44

Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
Temp A Warning Offset
0
(Time)
Temp B Warning Offset
1
(Time)
Temp C Warning Offset

(Time)
Temp B-A Warning Offset
3
(Time)
Temp C-A Warning Offset
4
(Time)
Group
Fan Control Range Setting (temp./Voltage)
254
10 Normal Fan Control Min
Temp
Normal Fan Control Max
11
Temp
1 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan Min
15 Normal Fan Max
0 Eco Fan Control Min Temp
1 Eco Fan Control Max Temp
 Eco Fan1 Min
3 Eco Fan1 Max
4 Eco Fan Min
5 Eco Fan Max
Group
Fan Start/Cooling Setting
255
0 Fan1 Initial Volt
1 Fan Initial Volt
4 Fan1 Cooling Speed
5 Fan Cooling Speed
8 Cooling Time L1
9 Cooling Time L
10 Temp Error Cooling Time
OnStart Cooling Start
11
Threshold
1 After shutdown cooling
Group
Fan Lamp Voltage down Setting
256
0 Lamp Voltage
1 Lamp Vol Threshold
 Fan1 Speed Gain
3 Fan Speed Gain
Group
Fan dimmer Setting
257
Dimmer Average Chech
0
Period
1 Dimmer Average
 Last Voltage Difference
3 Voltage Difference Goal
Group
FAN network mode IC temp.
258
0 Standby Cooling Check
Cycle
1 Standy Cooling Start
Threshold
 Standby Cooling Enable
Group
Auto Calibration (Common)* Auto Calibration
260
0 Execute Calibration
Function
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Tem.
p at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.
p at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L (x
30 sec) 1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Threshold to judge Lamp Voltage
Down ( V×10)
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
Dimmer Average measurement Time
(0:10sec. 1:30sec. :60 sec. 90:
sec...10:30sec.)
Dimmer Average Value (Read only)
Standby Cooling Check Cycle
Standy Cooling Start
Threshold
Standby Cooling Enable
Initial
3
3
3
3
3
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
46
45
39
38
50
49
44
43
7
7
115
115
135
135
135
135
80
80
110
110
130
130
130
130
46
45
39
38
50
49
44
43
5
5
100
100
115
115
10
10
65
65
75
75
85
85
91
91
70
70
100
100
3
4
4
38
1
-
0
10
10
1
-
-
-
5
55
1
0
-44-
Range Note
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
1-15
1-15
1-15
0-100
0-1
0-55
30-90
0-55
0-55
0-10
-
-
-
Executes Auto-Calibration when
0-1
changiing the Value (PC White
100%)