Electrical Adjustments
Group/
Item Name
Item
15
DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level
19 DIMMER_LEVEL_ECO
0 Lamp check enable
1 VOLTAGE_LEVEL
 DIMMER_LEVEL_HIGH
Group
VBI Slice Level
231
0 Generic Initial Slicing Level
Generic High Level Thresh-
1
old
 Generic Low Level Threshold PW190 register 0xE346
3 Generic Minimum Low Level
4 Generic Maximum High Level PW190 register 0xE348
Group
FAN Control
250
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
 FAN MIN ADJUST (DAC)
3 FAN MAX ADJUST (DAC)
6 Not used
7 Not used
Group
251
Not used
Group
Fan option
252
0 HI-LAND SWITCH
1 SAFETY SWITCH
 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 Not used
Group
Fan tem Error Setting (Memorized)
253
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal) Temp. B-A to judge the Temp Error at
9 Temp C-A Warning(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
17 Temp C Warning Offset
(Temp)
18 Temp B-A Warning Offset
(Temp)
19 Temp C-A Warning Offset
(Temp)
Function
Luminance Data Avarage Point for
Mimmer
Luminance Data Avarage Value for
Dimmer
Current Dimmer Leverl
Eco Dimmer Level
Lamp Voltage
Dimmer level High
PW190 register 0xE344
PW190 register 0xE345
PW190 register 0xE347
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land, -4: Hi-Land
1-3
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Initial
4
-
-
1
0
0
-
15
0x34
--
--
0x30
0xe0
10
4
44
5
0
0
0
100
100
-
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
55
55
47
46
60
59
54
53
70
70
65
64
100
100
100
100
100
100
100
100
55
55
47
46
60
60
55
54
71
70
66
65
100
100
100
100
100
100
100
100
8
8
8
8
8
-43-
Range Note
0 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
Unit: 8bit(Raw Data) * Read only
0 - 15
0-55
0-55
0-55
0-55
0-55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 5
0 - 6
0 - 3
0 - 55
0 - 55
0 - 55
30-100
30-100
30-100
0 - 100
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100

Advertisement