Clearances - Majestic fireplaces UVSRC36 Homeowner's Installation And Operating Manual

Ventless fireboxes

Advertisement

3a
UVSRC w/2" Hood
Ceiling
A
11" Min.
Combustible Perpendicular Wall
Front View
"
Standoff
Side View
Fig. 3 Clearances to combustibles.

Clearances

Sidewall Clearances:
The clearance from the side of the firebox to any
combustible wall extending in front of the unit should
not be less than 11". (Fig. 3)
Back Wall Clearances:
The firebox may be placed against a combustible back
wall.
Ceiling Clearances:
The ceiling height should not be less than 42" from the
top of the fireplace opening. (Fig. 3)
Mantel Clearances:
A 4" hood is furnished with each model firebox. This
hood MUST BE INSTALLED before using the firebox, if
a mantel falls within the dimensions and locations
shown in Figure 3. Refer to Accessories on Page 13.
If a combustible mantel or breast plate is installed, it
must meet the clearance requirements detailed in
Figure 3. If using a mantel with trim leg, maintain
clearances detailed in Figure 4.
20002068
3b
42"
Front View
Drywall
8"
Mantel
Shelf
F
B
C
2" Hood
Seal with noncombustible
material
UVSRC w/ 4" Hood
Ceiling
A
11" Min.
Combustible Perpendicular Wall
Drywall
8"
Mantel
Shelf
"
F
E
Standoff
Seal with noncombustible material
Side View
2"
Noncombustible
Facing Material
Front Edge of Grate
Fig. 4 Clearances to combustibles.
NOTE: When installing an ANSI Z21.11.2a ventless
appliance, the finishing material used for the mantel
must be rated at 250°F or greater.
Grate Clearance:
The minimum clearance between the front legs of the
grate and front edge of the fireplace is 3". (Fig. 4)
UVSRC Series Firebox
Dim. UVSRC36
A
36"
B
17"
C
12"
D
14"
42"
E
8 "
F
1 " max.
D
4" Hood (Includes Glass Hood)
Finished Wall
Combustible Mantel
Trim Leg
Firebox
3 "
3 "
Hood
3"
UVSRC42
42"
20"
16 "
15"
11"
1 " max.
FP604a
Combustible
Mantel Trim Leg
6"
8"
FP604b
5