Compressor Overload Protector Removal - Amana AAC051FRB Service Manual

Button down
Table of Contents

Advertisement

Disassembly Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and
discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures
require power to be connected. Ensure all ground wires are connected before certifying unit as repaired
and/or operational.
4. Unbraze condenser discharge connection to
compressor.
5. Unbraze condenser connection to capillary tube.
6. Lift condenser out and away at top from chassis.
Condenser
Compressor
Discharge
Connection
Capillary Tube
Connection
Condenser Removal

Compressor Overload Protector Removal

To remove compressor overload protector:
1. Remove outer case (see Outer Case Removal).
2. Remove nut securing terminal cover to
compressor, then lift terminal cover up and away
from compressor.
3. Disconnect overload protector leads.
4. Lift overload protector up and away from
compressor.
22
!
WARNING
Overload
Protector
Compressor Overload Protector Removal
Compressor Removal
To remove compressor:
1. Remove outer case (see Outer Case Removal).
2. Remove compressor overload protector (see
Compressor Overload Protector Removal).
3. Disconnect leads on compressor.
Note: Before opening any refrigeration system,
capture refrigerant in system for safe disposal.
4. Evacuate sealed system (see Evacuation in
Troubleshooting Information section).
To reduce risk of personal injury or property damage,
take nescessary precautions against high
temperatures required for brazing
16022379 Rev. 0
Terminal Cover
!
CAUTION
©2003 Maytag Appliances Company