Electrical Connections - Viessmann VITODENS 200-W Technical Data Manual

Natural gas and liquid propane gas gas-fired wall-mounted condensing boiler
Table of Contents

Advertisement

Venting Options/Electrical Connection/Control
Venting Options
For detailed information refer to the Installation Instructions for the Vitodens 200-W, B2HB Venting System.
Vent Connection, (with optional
air intake openings on sides)
for models B2HB 19, 26, 35

Electrical Connections

Power Supply
The Vitodens 200-W requires a standard 120 VAC power
outlet 15A fuse protected circuit. Refer to the installation
instructions shipped with the boiler for wiring details, or
reference the "Overview of Electrical Connections" on
pages 38 and 39 of this manual.
Power Supply Connection of Accessories
The power supply connection of accessories can be made
directly at the boiler control. The connection is activated
and deactivated with the system on/off switch.
The mixing valve accessory kit and the Vitosolic control
(if used) will require a separate 120 VAC power supply
from the wall receptacle.
16
Vitodens 200-W, B2HB 19 to 35 Technical Data
Wire cabling required for:
Outdoor temperature sensor
Vitotronic 200-H, HK1B mixing valve control
Accessory kit for heating circuit with mixing valve
Vitotrol 200 remote control
Vitotrol 300 remote control
Remote switching of operating mode
Remote disable
Alarm output