Download Print this page

Subaru 2004 LEGACY Service Manual page 9

Hide thumbs Also See for 2004 LEGACY:

Advertisement

Diagnostic Procedure with Diagnostic Trouble Code (DTC)
ENGINE (DIAGNOSTICS)
Step
6
CHECK FRONT OXYGEN (A/F) SENSOR.
1) Turn the ignition switch to OFF.
2) Measure the resistance between front oxy-
gen (A/F) sensor connector terminals.
Terminals
No. 2 — No. 1:
Check
Is the resistance less than 10
Ω?
EN(H6DO)(diag)-78
Yes
Repair the har-
Replace the front
ness and connec-
oxygen (A/F) sen-
tor.
sor. <Ref. to
FU(H6DO)-30,
NOTE:
Front Oxygen (A/
In this case repair
F) Sensor.>
the following:
• Open or ground
short circuit in har-
ness between front
oxygen (A/F) sen-
sor and ECM con-
nector
• Poor contact in
front oxygen (A/F)
sensor connector
• Poor contact in
ECM connector
• Poor contact in
coupling connector
No

Hide quick links:

Advertisement

loading