Sunbeam Pro Glide SR8700 User Manual page 12

Steam generator
Hide thumbs Also See for Pro Glide SR8700:
Table of Contents

Advertisement

Care and Cleaning continued
3. Slowly turn the calc clean boiler cap anti
clock wise. See fig 7.
Note: The boiler cap needs to be released
slowly to release any remaining water.
Figure 8
4. Remove the calc clean valve
completely. See fig 8.
5. Place the unit on its side and remove
any remaining water. Carefully pour
the descaling solution into the boiler.
Replace the calc clean valve.
6. Return the unit to the upright position
and leave for 2 minutes.
7. Shake the unit back and forth to
dislodge any scale build up on the base
of the boiler. Leave for 10 minutes.
8. Shake the unit again to swirl the
solution around inside the boiler.
9. Place the unit on a sink or vessel so
that water can be expelled from the
boiler.
10. Carefully remove the calc clean valve
and ensure the descaling solution is
emptied.
11. Rinse with 400ml of water (90 degrees
is recommended), shake and empty.
Repeat rinsing process at least 2
times.
12
12. Once you have completed the descaling
process, and refilled the tank, press
and hold the Power button for 3
seconds to switch off the Calc Clean
indicator light. The power light will
illuminate and the unit will begin
heating as normal.
Note: Sunbeam Steam Ironing System
descaling tablets (SR0100) are available
from selected department stores and
electrical retailers.
Calc Clean instructions – using lemon juice
Alternatively, if you do not have Sunbeam
Ironing System Descaling Tablets, you can
use lemon juice to remove the scale build
up from inside the unit's boiler.
1. To flush the boiler, turn the unit off
and wait for it to cool completely
(approx 2 hours).
2. Place the unit on a waterproof surface,
or on the edge of the sink.
3. Slowly release the calc clean boiler cap
to release any remaining water.
CAUTION: If the unit has been used prior to
descaling the boiler the calc clean boiler
cap will be very hot. Ensure that the unit
has cooled completely before commencing
the calc cleaning process.
4. Empty any remaining water from the
boiler.
5. In a small jug, add 3 tbs lemon juice
to 400ml of warm water (90 degrees is
recommended) and stir to mix.
6. Place the unit on its side and carefully
pour the lemon solution into the boiler.
Replace the calc clean boiler cap.
7. Return the unit to the upright position
and leave for 2 minutes.