Venting Installation - Superior MHW36R Installation And Operation Instructions Manual

Clean-face round back fireplace with bi-fold doors and combustion air kit
Table of Contents

Advertisement

OUTSIDE AIR KIT
Installation of an outside air kit should be
completed during the rough framing of
fireplace due to nature of its location. The
supplied flex duct measures approximately
10" compressed and up to approximately 36"
extended. Outside combustion air is accessed
through mobile home floor using air kit model
AK6E, included with the fireplace, or a side
wall using optional air kit model AK6-WE (see
Accessories on page 18).
Insert Inner Tab of
Inlet Tube into Slot
on Outer Surround
Left Side
Mounting
Shown
Secure to Collar with
Metal Tape, Screws or
Tie Straps
6

VenTing inSTallaTion

Insulation
Figure 6 - Outside Air Kit AK6-WE Installation
SuperiorFireplaces.US.com
Installer may choose either left or right side
mounting to allow for proper wall/rafter
clearances.
For AK6-WE Only: Construct a 4.5" x 4.5"
framing or opening on exterior wall (see
Figure 6, page 6).
For AK6E Only: The outside air vent is in-
stalled through a ventilated crawl space (see
Figure 7, page 7).
Outside
Air Vent
Termination
Air Vent Location
Must Allow
for Bushes,
Snow and
Other Possible
Obstructions
127312-01B