Superior MHW36CB Additional Instructions

Installing the chimney system

Advertisement

Quick Links

P/N 900284-00 Rev. NC 10/2014
P900284-00
INSTALLING THE CHIMNEY SYSTEM
Step 1. Before continuing, check the operation
of the damper, as described on Page 4, (refer
to Figure 2) of the Installation Instruction and
Care and Operations (IICO) manual.
Step 2. Using standard construction framing
techniques, construct opening for chimney
route up through the ceiling(s) and roof or
through an outside chase.
Framing must maintain adequate minimum air
space clearance at all times.
CAUTION
Allow minimum 1" chimney
air space to framing members
throughout chimney installation.
A minimum 1" air space must be
maintained from all insulation
and building materials extend-
ing for any continuous length
surrounding the chimney.
Reference Figures 10 and 11 in the IICO and
their charts for framing dimensions at Ceilings
and Roofs.
In new construction, to determine chimney center
line, use plumb line from roof or ceiling above
fireplace to center of flue collar on fireplace.
For remodeling, plumb to center of flue collar
from ceiling above, drive nail through ceiling
from below to mark position, then mark and
cut to passage from above ceiling (around
nail) (Figure 1). Then plumb from ceiling or
roof level directly above hole which has just
been completed.
Step 3. Position appropriate thimble/firestop
spacer combination at ceiling and nail temporar-
ily with two (2) 8d nails or equivalent fasteners
(see Figures 3, 4 and 5). Use one fastener on
opposite sides to hold thimble/firestop spacer
combination in position.
Addendum to Installation Instructions
Additional Instructions for Alternative Chimney
Installation for Superior™ Round Back Fireplaces with
Bi-Fold Doors and Combustion Air Kit
For use with Models
MHW36R
MHW36CB
Figure 1
Nail permanently, using at least two (2) more
fasteners, after chimney sections have been
assembled through the thimble/firestop spacer
combination and after any necessary adjust-
ments have been made. Firestop spacer must
be secured by at least four (4) fasteners when
completely installed.
Note: If there is a room above ceiling level,
firestop spacer must be installed on the bottom
side of the ceiling. If an attic is above ceiling
level, firestop thimble must be installed on the
bottom side of ceiling joist (Figure 2).
Room Above
Figure 2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 3
14" Min.
Note: Trim Thimble/
Extension To Desired Length
And Pitch At The Rood Line
14" Min.
Firestop Spacer
F8FS-2
Attic Above
1"
Clearance
Minimum
Firestop Thimble
Outer Pipe Of
Chimney
Thimble
FM8-AT1
Pitched Roof
Outer Pipe Of
Chimney
14" Min.
Thimble
Extension
F8-TE26
Thimble
FM8-AT1
Pitched Roof
Outer Pipe Of
Chimney
Thimble
FM8-AT1
Bow Roof
Figure 4
13"
1

Advertisement

loading

Summary of Contents for Superior MHW36CB

  • Page 1 Addendum to Installation Instructions Additional Instructions for Alternative Chimney Installation for Superior™ Round Back Fireplaces with Bi-Fold Doors and Combustion Air Kit P/N 900284-00 Rev. NC 10/2014 For use with Models MHW36R MHW36CB P900284-00 INSTALLING THE CHIMNEY SYSTEM Attic Above Step 1.
  • Page 2 Note: The installation of the thimble extension At all subsequent joints, the upper flue section fits into the preceding flue section. Each piece (F8-TE26 in the US or F8-TE26-2 in Canada ) snaps together by means of locking tabs (9 is not required in manufactured homes having locking tabs per joint).
  • Page 3 Next, slide roof flashing over extended chimney Seal storm collar to outer chimney with roof 2. Center inner slip section in inner flue pipe- caulking or mastic around entire circumfer- section that previously has been installed above slip down. ence of pipe. Also add extra roof caulking to the roof opening in Step 4.
  • Page 4 If the horizontal distance from the peak of the SPECIAL OFFSET INSTRUCTIONS A 1/8" diameter hole must be drilled in the roof is less then 10', the top of the chimney must chimney joint using a 1/8” diameter drill. Hole be at least 2' above the peak of the roof.
  • Page 5 FTF8 VERTICAL ELEVATION CHART Height Of Chimney Number Of FTF8 Height Of Height Of Chimney Number Of FTF8 Height Of Only Chimney Components Chimney Only Chimney Components Chimney Only Only Inches Feet/Inches 12" 18" 24" 36" 48" Meters Inches Feet/Inches 12"...
  • Page 6 FTF8 OFFSET ELEVATION CHART FTF8-S4 Number of FTF8 Chimney Sections Offset Offset Stabilizer Offset Offset 12" 18" 24" 36" 48" (inches) (inches) (meters) (meters) – 0.10 0.40 – 0.23 0.63 – 0.31 0.76 – 0.36 0.85 – 0.38 0.89 – 0.44 0.98 –...
  • Page 7 Offset Elbow Assembly NOTES Offset elbows install the same as chimney sections. First, snap the inner section INTO the preceding inner section of flue. Check connec- tion by pulling up slightly to ensure a tight fit. Next, the outer sections snap lock OVER the preceding outer section of chimney.
  • Page 8 INSTALLATION COMPONENTS Firestop Spacer (30°) 63L30 F8FS30 Firestop Spacer (30°) 63L32 F8FS30-2** 91L46 F8-TE26 Thimble Extension 26" 19M52 F8-TE26-2** 63L10 FTF8-12 63L13 FTF8-18 H0522 FTF8-24 63L14 FTF8-36 63L15 FTF8-48 63L92 FTF8-18C** Chimney Section 63L93 FTF8-36C** Storm Collar 63L59 Storm Collar (12 pack) 94L77 FSC-B-12 Contemporary Termination -...