Front Panel Features - Mackie DX8 Instruction Manual

Digital audio mixer/ signal processor with automixing
Hide thumbs Also See for DX8:
Table of Contents

Advertisement

FRONT PANEL FEATURES

INPUT UP/DOWN BUTTONS
Use these buttons to adjust the mix level for each
input channel.
INPUT LED DISPLAY
This indicates the signal level after the mic preamp
stage, just after the A/D converter, but prior to any
digital signal processing. When any input UP/
DOWN button is pressed, all the meters (except
EQ) switch from level metering to level setting
indication. After five seconds, the meters switch
back to normal peak program metering (PPM).
When the 10 and 7 LEDs are both lit, the gain is set
to unity (0 dB).
EQ LO/HI UP/DOWN BUTTONS
Use these buttons to adjust the gain of the 2-band
shelving EQ on the outputs. The range is ± 15 dB.
OL
2
4
7
10
15
20
25
30
35
40
50
1
THE FOLLOWING ARE TRADEMARKS OR REGISTERED
TRADEMARKS OF MACKIE DESIGNS INC "MACKIE",
"MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE
CONCEIVED, DESIGNED, AND MANUFACTURED
BY MACKIE DESIGNS INC WOODINVILLE • WA • USA
MADE IN USA • FABRIQUE AU USA • COPYRIGHT ©1999
100
240V
, 50/60Hz, 1A MAX
LISTED COMMERCIAL
AUDIO EQUIPMENT
R
9Z39
DX8 – 4
OL
OL
OL
2
2
2
4
4
4
7
7
7
10
10
10
15
15
15
20
20
20
25
25
25
30
30
30
35
35
35
40
40
40
50
50
50
2
3
4
1
2 3 4 5 6 7 8
DIRECT OUTPUTS
U
U
-20
+20
-20
+20
- 30dB +30dB
TRIM
TRIM
BUS A
BUS B
MIC
POWER
+ G
INPUT
LINE
22-28V DC,
G
+
3A MAX
+
LINE
LINE
EQ LED DISPLAY
When an EQ UP/DOWN button is pressed, the EQ
meter indicates the amount of boost or cut of the
LO and HI frequencies in decibels (± 15 dB).
When both "0" LEDs are lit, the gain is set to unity
(flat response).
Note: The EQ meters do not indicate signal level.
MASTER A/B UP/DOWN BUTTONS
These buttons adjust the output level for each
output bus.
MASTER OUTPUT LED DISPLAY
This indicates the signal level after the digital signal
processing and MASTER gain stage, just prior to
the D/A converter. When any MASTER UP/DOWN
button is pressed, all the meters (except EQ) switch
from level metering to level setting indication. After
five seconds, the meters switch back to normal
peak program metering (PPM).
OL
OL
OL
2
2
2
4
4
4
7
7
7
10
10
10
15
15
15
20
20
20
25
25
25
30
30
30
35
35
35
40
40
40
50
50
50
5
6
7
DX8 DIGITAL MIXER
U
U
U
0
60
0
60
0
60
0
- 30dB +30dB
- 30dB +30dB
- 30dB +30dB
TRIM
TRIM
TRIM
TRIM
1
2
3
MIC
MIC
MIC
MIC
LINE
LINE
LINE
LINE
15
12
9
6
3
0
3
6
9
12
15
8
LO
EQ
HI
SERIAL NUMBER
MANUFACTURING DATE
U
U
U
U
60
0
60
0
60
0
- 30dB +30dB
- 30dB +30dB
- 30dB +30dB
TRIM
TRIM
TRIM
4
5
6
7
MIC
MIC
MIC
LINE
LINE
LINE
OL
2
4
7
10
15
20
25
30
35
40
50
A
MASTE
U
60
0
60
- 30dB +30dB
TRIM
8
MIC
LINE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents