1) STOP! Read the safety information on the side of the boiler. DO NOT START THE
BOILER UNLESS ALL CLEANOUT DOORS ARE SECURED AND SEALED.
(Skip to step 9 for oil burning boilers)
2) Set thermostat to lowest setting
3) Turn off all electric power to the appliance
4) Do not attempt to light the burner by hand
5) Turn the manual shut off on
the off position.
6) Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow "B" in the safety information above on this label. If you
don't smell gas, go to the next step.
7) Return the manual valve on the combination gas valve to the on position by reversing
step "5".
8) Turn on all electric power to the appliance.
9) Set thermostat to the desired setting.
10) If the burner fails to light you may press the reset button once. If the appliance will not
operate, follow the instructions "To Turn Off Gas To Appliance" and call your service
technician or gas supplier. DO NOT ATTEMPT TO START THE BURNER WHEN
EXCESS OIL HAS ACCUMULATED, WHEN THE UNIT IS FULL OF VAPOR, OR
WHEN THE COMBUSTION CHAMBER IS VERY HOT.
NOTE: ALWAYS KEEP THE MANUAL FUEL SUPPLY VALVE SHUT OFF IF THE
BURNER IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME.
1) Set the thermostat to the lowest setting.
2) Turn off electric power to the appliance if service is to be performed.
Turn the gas control valve to the off position.

17. Homeowner Information

TO TURN OFF GAS APPLIANCE
the combination gas valve clockwise to
Biasi SG Series