Fisher FP-120AE-R Service Manual page 9

Portable type
Table of Contents

Advertisement

E3- Condenser temperature sensor error- Unplug the unit and plug it back in. If error repeats, call for
service
E4- Display panel communication error- Unplug the unit and plug it back in. If error repeats, call for service.
P1- Bottom tray is full - Connect the drain hose and drain the collected water away. If error repeats,
call for service.
(9) FOLLOW ME/TEMP SENSING feature(optional)
NOTE: This feature can be activated from the remote control ONLY. The remote control serves as a
remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press
the Follow Me/Temp Sensing button. The remote display is actual temperature at its location. The
remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow
Me/Temp Sensing button again. If the unit does not receive the Follow Me /Temp Sensing signal during
any 7 minutes interval, the unit will beep to indicate the Follow Me/Temp Sensing mode has ended.
(10) POWER MANAGEMENT feature(optional)
When the ambient temperature is lower (Cooling mode) than the setting
temperature for a period of time, the unit will be automatically operate power management feature. The
compressor and fan motor stop and the power management indicator light illuminates. When the
ambient temperature is higher (Cooling mode) than the setting temperature, the unit will be
automatically quit the power management feature. The power management indicator light turns dark
and the compressor and (or) fan motor run.
7

Advertisement

Table of Contents
loading