Technical Service; Specifications; Service Hints - Desa CF18PV Owner's Operating & Installation Manual

Unvented vent-free propane gas log heater
Table of Contents

Advertisement

TECHNICAL
SERVICE

SPECIFICATIONS

SERVICE
HINTS
34
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at
1-800-DESA LOG (1-800-337-2564).
18" Thermostat- 24" Thermostat- 30" Thermostat-
Controlled
Btu (Variable)
16,000/26,000
Type Gas
Propane Only
Ignition
Piezo
Pressure Manifold
7.9" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
14"
Minimum*
11"
* For purpose of input adjustment
Shipping Weight
36 lbs.
18" Variable
Manually-
Controlled
Btu (Variable)
16,000/26,000
Type Gas
Propane Only
Ignition
Piezo
Pressure Manifold
7.9" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
14"
Minimum*
11"
* For purpose of input adjustment
Shipping Weight
29 lbs.
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.
Controlled
Controlled
20,000/33,000
21,500/36,000
Propane Only
Propane Only
Piezo
Piezo
7.9" W.C.
7.9" W.C.
14"
14"
11"
11"
38 lbs.
40 lbs.
24" Variable
30" Variable
Manually-
Manually-
Controlled
Controlled
20,000/33,000
21,500/36,000
Propane Only
Propane Only
Piezo
Piezo
7.9" W.C.
7.9" W.C.
14"
14"
11"
11"
31 lbs.
39 lbs.
102653