Convergence Adjustment; Power Saving Function Inspection - Mitsubishi Diamond Plus 93SB Service Manual

Hide thumbs Also See for Diamond Plus 93SB:
Table of Contents

Advertisement

14. Convergence Adjustment

CH : Convergence error of horizontal direction
CV : Convergence error of vertical direction
(1) Receive signal 12 (Cross hatch pattern).
(2) Measure convergence error. If it is out of spec, adjust convergence by 4-pole magnets and 6-pole
magnets.
A Zone (A circle 236mm in the center of the CRT face center)
CH, CV : Within 0.25mm
B Zone (Areas outside of zone A within the rectangle of 356mmx266mm)
CH, CV : Within 0.30mm

15. Power Saving Function Inspection

(A) Mode: No.13
(B) Pattern: Full white
(C) Input: Maximum rating voltage
(D) Inspection
1. It should be into power off Mode when the both horizontal sync and vertical sync are disable after
8 seconds. Check the LED color "Orange" and the power consumption must be less than 5W.
2. It should be recovered the normal Mode when the both horizontal sync and vertical sync are enable.
Check the picture is normal and LED color "Green".
A
B
356mm
Cv
266mm
4-9
C
H