Sanyo PLC-XP50 Service Manual page 14

Hide thumbs Also See for PLC-XP50:
Table of Contents

Advertisement

Electrical Adjustments
No.
Adjustment Item
5
G_V1
6
B_V1
7
R_V1
8
G_V2
9
B_V2
10
R_V2
11
G_CLMP
12
B_CLMP
13
R_CLMP
14
SGAIN +
15
SGAIN -
16
LF_LEV
255 / 255 / 255 / 0 / 0
17
DAC_VRB
18
DAC_GY
19
DAC_BCB
20
DAC_RCR
Group: 6 TC90A69F
0
Y-EQ_GAIN
1
Y-EQ_N_C_LIM
2
V-ENH_GAIN
3
V_ENH_CORING
4
NTSC443_SW
Group: 10 Option
0
Lamp Time Monitor
1
RS232C Baudrate
2
Shootout Mode
3
Cooling Time
4
Hi-Land SW
5
V-Douki SW
6
Lamp Total Time
7
Net Board RESET
8
Keystone Option
9
Syukka SW
10
Color Shading SW
11
RC Enable/Disable
12
Lamp Dim Level
13
Lamp Warning Time
14
Forced NOBRAND
15
Forced Video Mute Off
16
ANZEN FAN Control Fix SW
17
DJTR_SW
18
HDCP Option
19
HDCP Reset
Group: 11 FAN (Fan Control)
0
FAN_TEMP_A_WARNING
1
FAN_TEMP_B_WARNING
2
FAN_TEMP_C_WARNING
3
FAN_TEMP_B-A_WARNING
4
FAN_TEMP_C-A_WARNING
5
FAN_CONTROL_SW
6
FAN1 Manual Out
7
FAN2 Manual Out
8
FAN4 Manual Out
9
FAN5 Manual Out
10
FAN6 Manual Out
11
FAN7 Manual Out
12
FAN1 Now Out
13
FAN2 Now Out
14
FAN4 Now Out
15
FAN5 Now Out
16
FAN6 Now Out
17
FAN7 Now Out
18
Temp Monitor A
19
Temp Monitor B
20
Temp Monitor C
21
Pressure Monitor
22
FAN_BALLAST_SW
23
Service Target MODE
24
Service Target FAN
25
Control Switch
26
Temp Source Range High
27
Temp Source Range Low
Initial Value
Range
134
0 ~ 255
134
0 ~ 255
134
0 ~ 255
154
0 ~ 255
154
0 ~ 255
154
0 ~ 255
125 / 210 / 210 / 210
0 ~ 255
181 / 160 / 220 / 225
0 ~ 255
184 / 160 / 220 / 225
0 ~ 255
-
0 ~ 255
128
0 ~ 255
0 ~ 255
35
0 ~ 255
110 / 115 / 115
0 ~ 255
110 / 115 / 115
0 ~ 255
110 / 115 / 115
0 ~ 255
3
0 ~ 3
3
0 ~ 3
4
0 ~ 7
2
0 ~ 3
1
0 ~ 1
-
0 ~ 8738
0
0 ~ 1
0
0 ~ 1
3
0 ~ 15
0
0 ~ 1
0
0 ~ 1
-
0 ~ 65535
1
0 ~ 1
0
0 ~ 1
0
0 ~ 10
1
0 ~ 1
0
0 ~ 3
15
0 ~ 15
1500
0 ~ 65535
0
0 ~ 1
0
0 ~ 1
0
0 ~ 4
-
-
0
0 ~ 3
0
0 ~ 10
460
30 ~ 1000
800
30 ~ 1000
510
30 ~ 1000
520
0 ~ 1000
200
0 ~ 1000
0
0 or 1
1350
0 ~ 2000
1350
0 ~ 2000
1350
0 ~ 2000
1350
0 ~ 2000
1350
0 ~ 2000
1350
0 ~ 2000
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0
0 or 1
-1
-1 ~ 3
0
0 ~ 5
0
400
330
Input source / Description
DAC2
DAC2
DAC2
DAC2
DAC2
DAC2
PC(not RGB Video) / RGB Video / Video, SCART / Component
PC(not RGB Video) / RGB Video / Video, SCART / Component
PC(not RGB Video) / RGB Video / Video, SCART / Component
SCART / RGB-480i,575i / YCbCr-480i,575i / VIDEO,S-VIDEO / Others
Composite, SCART / Component / RGB Video
Composite, SCART / Component / RGB Video
Composite, SCART / Component / RGB Video
0 : NTSC4.43 1 : PAL60 (Available for NTSC4.43)
Read only
0: 19200bps
1: 9600bps
0: Disable 1: Enable
Set cooling period, 1: 30 sec. 3: 90 sec. 15: 450 sec. 0: continuos
0: Normal 1: Highland mode (Fan spin speed max.)
0: Synchronized Vertical 1: non-synchronized Vertical
Read only
0: Disable
1: Enable
0: Maximum correction (fix) 1: Changeable for Input signal
Set 10 to Shipping Condition
0: OFF 1: ON
0: Both enable 1: Front Disable 2: Rear Disable 3: Both Disable
0: the darkest 1: the brightest
Unit = hour
0: Normal 1: No brand
0: Video Mute ON 1: Video Mute OFF
0: Normal 1: Normal min. 2: Normal max 3: Eco min. 4: Eco max
Not used
0: XGA 1: Not XGA
Set 10 and write EDID Data for HDCP
Temperature to judge abnormal A (Not memorized) Inside projector
Temperature to judge abnormal A (Not memorized) Lamp
Temperature to judge abnormal A (Not memorized) LCD Panel
0: Auto-control all Fans 1: Manual control all Fans
These are effective when FAN_CONTROL_SW is set to "1".
Read only Reading voltage of each Fan
Read only
Read only
Fan control depend on Ballast Output Voltage 0: OFF 1: ON
-1: Current Mode 0: Normal Mode 1: Eco Mode
Service target 0: FAN1 1: FAN2 2: FAN4 3: FAN5 4: FAN6 5: FAN7
Control Switch for the operated Fan 0: Auto 1: Manual
Control range of Temperature for Temperature Sensor A
-14-
Video center adjustment [G]
Video center adjustment [B]
Video center adjustment [R]
Video center adjustment [G]
Video center adjustment [B]
Video center adjustment [R]
Y/G pedestal adjustment
Cb/B pedestal adjustment
Cr/R pedestal adjustment
A/D reference voltage bottom adjustment
A/D reference voltage top adjustment
Fan adjustment [Setting]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xp50l

Table of Contents