Controlling the Monitor with a PC (RS-232C)

MONITOR menu

Function
MONITOR
STANDBY MODE
OFF IF NO OPERATION

OTHERS menu

Function
SCREEN
PATTERN
MOTION
MOTION TIME 1
MOTION TIME 2
POWER MANAGEMENT
SIZE
MUTE AUDIO
INFORMATION MODEL
SERIAL NO
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
Others
Function
VOLUME
BRIGHT
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
26
E
Parameter
Command
Direction
STDR
WR
0-1
STBM
WR
0-1
ATOF
WR
0-1
Command
Direction
Parameter
SCSV
WR
0,2,3
MTIM
WR
0-20
MINT
WR
5-20
PMNG
WR
0-1
WIDE
WR
1-3
MUTE
WR
0-1
INF1
R
SRNO
R
Command
Direction
Parameter
RSET
W
0
ALCK
WR
0-2
LOSD
WR
0-2
OFLD
WR
0-1
TALT
WR
0-2
SALT
WR
0-2
Command
Direction
Parameter
VOLM
WR
0-31
VLMP
WR
0-31
DSTA
R
ERRT
R
STCA
W
0
R
Reply
Control/Response contents
0-1 0: LANDSCAPE, 1: PORTRAIT
0-1 0: STANDARD, 1: LOW POWER
0-1 0: OFF, 1: ON
Reply
Control/Response contents
0,2,3 0: OFF, 2: PATTERN1, 3: PATTERN2
0-20
5-20 Per second
0-1 0: OFF, 1: ON
1-3 1: WIDE, 2: NORMAL, 3: Dot by Dot
0-1 0: OFF, 1: ON
Value
Value
Reply
Control/Response contents
0-2 0: OFF, 1:ON 1, 2:ON 2
0-2 0: ON 1, 1: OFF, 2: ON 2
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
Reply
Control/Response contents
0-31
0-31
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in
standby mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting
*
*
-
*
-
*