Connecting The Room Thermostat; Connecting The Opentherm; Connecting The Outdoor Temperature Sensor; Opentherm® Protocol - Navien NCB-24LSWE Installation & Operation Manual

Condensing combi boiler
Hide thumbs Also See for NCB-24LSWE:
Table of Contents

Advertisement

7.4 Connecting the Room Thermostat

The boiler is designed to be connected to a room thermostat.
The thermostat cables are to be connected to terminals 1 and
2 of the boiler terminal strip, removing the electrical bridge
originally supplied.

7.5 Connecting the OpenTherm

The boiler is designed to be connected to a OpenTherm. The
OpenTherm cables are to be connected to terminals 3 and 4 of
the boiler terminal strip, removing the electrical bridge originally
supplied.
Detail View
1
2
3
4
5
6
Detail View
1
2
3
4
5
6
7.6 Connecting the Outdoor Temperature
Sensor
The boiler is designed to be able to function with an outdoor
temperature sensor. The sensor cables are to be connected
to terminals 5 and 6 of the boiler terminal strip, removing the
electrical bridge originally supplied.
7.7 OpenTherm® Protocol
OpenTherm® is an industry standard modulating control
available from several control manufacturers and the NCB
LSWE boiler has an OpenTherm® interface. This enables
our modulating range of OpenTherm® room controls to be
connected without any further modifications.
1
2
3
4
5
6
OpenTherm Protocol
NCB LSWE
Detail View
1
2
3
4
5
6
Room Controller
Connecting Electrical Supplies
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncb-34lsweNcb-28lsweNcb-40lswe

Table of Contents