Yearly Maintenance (or every two tons) - continued

Clean the Exhaust Blower

The exhaust blower cover is held in place with 4 screws.
Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.
Remove these 3 nuts to
expose the exhaust blower.
Flow Switch Tube
Nipple (attached to exhaust channel)
Travis Industries
Maintenance
Check the nipple and flow switch tube. Insert a pipe
cleaner through the nipple to dislodge any flyash.
NOTE: The flow switch will shut off the auger if the
tube becomes clogged or dislodged. Make sure it is
cleaned out and correctly attached.
4061016
Remove the
side cover.
Use the bottle brush to disoldge any
flyash near the exahust blower and in the
horizontal exhaust channel. Take care
to not damage the impeller on the
exhaust blower.