Restrictor Adjustment; Adjusting The Fan Speed - Lopi Leyden Pellet Stove User Manual

Lopi leyden pellet stove user guide
Table of Contents

Advertisement

2 4

Restrictor Adjustment

The restrictor "fine tunes" your appliance, adjusting the amount of air flowing to the flame.
NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
Not Enough Air
If clinkers (ashes that solidify into
a clump) develop or the flame
appears lazy and slow to blow the
ash out of the firepot, pull the
restrictor outward until the flame
becomes active and the firepot
holes remain clean. NOTE: If the
restrictor is fully out, yet the
firepot does not remain clean,
the stove needs to be cleaned
and checked for air leaks (see
"Maintenance" section of this
manual).
Too Much Air
If the flames are too active (small,
flickering flames) or if burning
pellets are expelled from the
firepot, move the restrictor rod
inwards until the flame slows
down and no burning pellets are
expelled. Another symptom of
too much air is the heater
"blowing the fire out" – a
condition in which the pellets
burn faster than they are fed (this
is most common on low).

Adjusting the Fan Speed

Travis Industries
Operation
AUTO
UP
OFF
H
MANUAL
E
A
T
MANUAL
DOWN
START
UP
F
MANUAL
A
N
DOWN
AUGER
TM
TRAVIS INDUSTRIES
HOUSE OF FIRE
4061016
Press the "up" or "down"
button to adjust the fan
speed.
NOTE: When adjusting
the fan speed the HEAT
OUTPUT lights will flash