Installation Example: Direct "Through-The-Wall" Installation - Lopi Leyden Pellet Stove User Manual

Lopi leyden pellet stove user guide
Table of Contents

Advertisement

Installation
1 4

Installation Example: Direct "Through-the-wall" Installation

Horizontal Rain Cap
Wall Thimble
(note 3" clearance
between vent and
combustibles)
12"
Minimum
Travis Industries
(For Qualified Installers Only)
Type "L" Vent
12" Minimum
3" Minimum
7" Minimum
6" Minimum
3" Minimum
17-1/4"
4061016
House Shield (used to protect
exterior wall from soot
discoloration) is HIGHLY
RECOMMENDED
Floor Protection
Floor Protection
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.
1 0 0 - 0 1 1 8 4