Yearly Maintenance (or every two tons)
WARNING:
Disconnect the power cord prior to conducting service.
The following section details extensive maintenance procedures. We strongly suggest these items
be carried out by a trained service technician, possibly by a service agreement set up with your dealer.
Soot and Flyash: Formation and Need for Removal – The products of combustion will
contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the
flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect
operation of the room heater will lead to some soot formation which will collect in the exhaust venting
system The exhaust venting system should be inspected at least once every year to determine if
cleaning is necessary.
Clean the Vertical Exhaust Duct
Clean the Exhaust Duct
Travis Industries
Maintenance
(the stove must be cool and unplugged)
Remove both
refractory clips.
(make sure the heater is cool and unplugged)
Phillips
Screwdriver
Swing open this panel to
access the door latch (use
the tool if necessary).
4 0 5 0 5 0 9
Clean the refractory and
the entire area behind it
(both sides).
c
Remove the
cover plates over
the exhaust duct
(both sides)
Cover Plate
7/16" Nutdriver
Remove these doors to
remove fallen flyash and
soot (see "Bi-Weekly
d
Use a vacuum or bottle
brush to remove all
flyash from the exhaust
duct (if the gasket is
damaged, replace).