Typical Vent Installations; Special Vent Installations - Napoleon Vittoria GD19N Installation And Operation Instructions Manual

Table of Contents

Advertisement

6
VENTING LENGTHS AND AIR TERMINAL LOCATIONS CONTINUED
When using Wolf Steel venting components, use only
approved Wolf Steel rigid / fl exible components with the
following termination kits:Wall Terminal Kit
1/12 to 7/12 Pitch Roof Terminal Kit GD110, 8/12 to 12/12
Roof Terminal Kit GD111, Flat Roof Terminal Kit GD112 or
Periscope Kit GD201 (for wall penetration below grade).
With fl exible venting, in conjunction with the various
terminations, use either the 5 foot Vent Kit GD220 or the 10
foot Vent Kit GD330.
The maximum allowable vertical vent length is 35 feet.
For optimum fl ame appearance and fi replace performance,
TYPICAL VENT
INSTALLATIONS
REAR EXIT
FIGURE 2a
16"
MINIMUM
35 FT MAXIMUM
3 FT MINIMUM
For optimum performance, it is recommended that all
horizontal runs have a 1" rise per foot.
When terminating vertically, the vertical rise is a minimum 3 feet and
a maximum 35 feet from the centre of the fi replace fl ue outlet.
20" MAXIMUM
3
26
/
" MINIMUM
8
PLUS RISE*
FIGURE 3a
* Refer to "Venting" section.
W415-0612 / A / 11.05.07
GD222, or
TOP EXIT
FIGURE 2B
16"
MINIMUM
35 FT MAXIMUM
3 FT MINIMUM
24" MAXIMUM
10"
MINIMUM
43
7
/
" MINIMUM
8
PLUS RISE*
FIGURE 3b
keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times.
Examine the air terminal at least once a year to verify that it
is unobstructed and undamaged.
Horizontal runs may have a 0 inch rise per foot in all cases
using Wolf Steel or Simpson Dura-Vent rigid, Selkirk Direct
Temp, American Metal Amerivent or Wolf Steel fl exible
venting components when venting.
For optimum performance, it is recommended that horizontal
runs have a minimum 1" rise per foot when using any of
these vent systems.
SPECIAL VENT
INSTALLATIONS
PERISCOPE TERMINATION
Use the GD201 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a
minimum of 12" above grade. The maximum allowable vent
length is 10 ft.
FIGURE 4a
12"
MINIMUM
24"
MINIMUM
MAXIMUM 10FT VENT LENGTH
TOP EXIT INSTALLATION
CORNER TERMINATION
The maximum vent length for a corner installation is 20" of
horizontal run, in addition to the 45° offset. In this case zero
rise is acceptable when using rigid. See FIGURE 5a. Flexible
venting must maintain a 6" rise. See FIGURE 5b.
FIGURE 5a
20" MAXIMUM
FIGURE 4b
12"
MINIMUM
24"
MINIMUM
REAR EXIT INSTALLATION
FIGURE 5b
6" RISE
MINIMUM