INSTALLATION
Continued
LOCATING HEATER
This heater is designed to be mounted on
a wall.
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from floor,
ceiling and joining wall.
WARNING: Never install the
heater
• in a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other flammable
objects are less than 36" from
the front, top or sides of the
heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" above floor
• locate heater where moving
vehicle will not hit it
CEILING
8"
(20.3 cm)
Minimum
From
Sides Of
Heater
Left
Side
FLOOR
Figure 4 - Mounting Clearances As
Viewed From Front of Heater

36" (91.5 cm)
Minimum
Right
Minimum To
Side
Top Surface
Of Carpeting,
Tile Or Other
Combustible
3" (7.7 cm)
Material
www.desatech.com
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 5. If high humidity is experienced,
a dehumidifier may be used to help lower the
water vapor content in the air.
For convenience and efficiency, install heater
• where there is easy access for operation,
inspection and service
• in coldest part of room
INSTALLING HEATER TO WALL
Marking Screw Locations
1. Determine where you will locate heater.
WARNING: Maintain mini-
mum clearances shown in Figure
5. If you can, provide greater
clearances from floor and join-
ing wall.
2. Mark two mounting screw locations on
wall (see Figure 5).
10
/
"
7

Minimum To
Maintain 8"
Clearance
From Wall
FLOOR
Figure 5 - Mounting Screw Locations
7
/
"
3
4
20
/
1
Mounting
Minimum To
Screw
Maintain 3"
Locations
Clearance
From Floor
107902-01L
"
4