General Information; Availability - Lochinvar Hot Water Generator Installation And Operation Manual

Lochinvar hot water generator installation and operation manual
Table of Contents

Advertisement

1

General information

• Before using product, read and
WARNING
understand instructions.
• Save these instructions for future
reference.
• All work must be performed by
qualified personnel trained in the
proper application, installation, and
maintenance of steam systems and/or
boiler water systems in accordance with
all applicable codes and ordinances.
• To prevent serious burns, wear heat
resistant gloves when opening and
closing steam valves, or handling hot
equipment.
• To prevent serious burns, the internal
pressure of the trap must be 0 psi
(0 bar) before servicing.
• To prevent serious personal injury from
steam pipe blow down, connect a
temporary pipe between the steam pipe
opening and a drain, or stand at least
100 ft. (30 m) from the front of the pipe
opening.
• To prevent property damage, personal
injury, or death, cap off the gate valves
if they are not connected to a drain and
when they are not in use for test or
pressure relief.
Failure to follow this warning could cause
property damage, personal injury, or
death.
This manual is intended to cover installation, operation, and
maintenance procedures for Lochinvar's Hot Water Generator
Systems.
Since each unit is built to meet customer
specifications, instructions may not be specific to every
system.
If questions are not answered by this manual, or if specific
installation, operation, and/or maintenance procedures are
not clearly understood, contact Lochinvar for clarification
before proceeding.
These Hot Water Generator Systems are designed for indoor
use only, unless otherwise required by design specifications.
Each unit requires at least two feet of clearance around and
above the unit. It should be located on a level surface (no
more than one-half degree of slope), capable of supporting
the total weight of the unit when filled to capacity.
The unit should be mounted to the floor following applicable
architectural and local code requirements for the specific
installation site. Note: Tanks do not come standard with floor
tie downs.
Hot Water Generator Installation Instructions
The high quality enamel paint, applied to the jacket of the
unit, will provide years of protection against corrosion. If it is
necessary to clean the outside of the unit, a mild cleaning
agent should be used that will not damage the paint.
For all piping connections, the use and/or type of joint
compound or sealer on the joints should be determined by
referring to local codes, accepted standards, and/or the
requirements of the installing contractor.
Lochinvar's Hot Water Generator Systems are ideal when
boiler capacity is sufficiently sized to cover potable hot water
demand and provide source water for hydronic heating
systems. Hot Water Generator Systems use steam or boiler
water as an energy source and can provide high recovery rates,
making them an economical water heating system for end
users.

Availability

Hot Water Generator Systems are pre-engineering and pre-
assembled complete with all piping to meet your specific
application. And like every Lochinvar product, we thoroughly
test them to ensure proper performance from the moment
they are installed.
Hot Water Generator Systems are available in horizontal or
vertical configurations (see FIG.'s 1 and 2) in a wide array of
gallon capacities. Standard packages are available in tank sizes
from 200 - 1000 gallons with single wall copper tube bundle
heating units. Custom configurations, smaller and larger tank
and tube bundles, and optional control packages are also
available. Consult the factory for specifications.
Tank Construction -- Lochinvar tanks are available with glass
or cement lining.
ASME -- All Lochinvar tanks are constructed in accordance
with ASME standards and certified for 125 psi working
pressure (standard) or 150 psi working pressure (optional).
Cathodic Protection -- All glass lined tanks are equipped
with magnesium anodes to provide protection against
corrosion.
Manway - A manway is provided as an option on glass lined
tanks and is standard on cement lined tanks.
*Horizontal tanks with tube bundles 48" and longer require a
manway.
Tank Circulator Package -- All standard Hot Water Generator
Systems are equipped with a circulator package to maximize
the amount of hot water provided.
Five-Year Limited Tank Warranty -- Provides warranty
protection against tank failure (see warranty for details).
One-Year Limited Warranty -- Tube Bundle, parts,
accessories and controls (see warranty for details).
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents