<007: ATT transmission level>
Use it to set the transmission level (ATT).
Raise the transmission level if errors occur frequently at time of communication because of
the condition of the line. (It means close to 8)
MEMO:
Any of the following error codes may be indicated at time of transmission because of
the line condition:
##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750,
##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,
##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784,
##785, ##787, ##789
Any of the following error codes may be indicated at time of reception because of the
line condition:
##103, ##106, ##107, ##201, ##793
##103, ##106, ##107, ##201, ##793
<008: V.34 modulation speed upper limit>
Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primary
channel.
<009: V.34 data speed upper limit>
Use it to set an upper limit to the data transmission speed for the V.34 primary channel
between 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:33.6K bps).
<010: Frequency of the pseudo CI signal>
You may select a frequency for the pseudo CI signal.
Some types of external telephones do not ring when the fax/tel switch-over function is ON.
To sound the ring, change the pseudo CI signal.

#NUMERIC

Numerical Parameter Composition

No.
Item
002
RTN transmission condition(1)
003
RTN transmission condition (2)
004
RTN transmission condition (3)
005
NCC pause time length (pre-ID code)
006
NCC pause time length (post-ID code)
010
line condition identification time length
011
T.30T1 timer (for reception)
013
T.30 EOL timer
015
hooking detection time length
016
time length to first response at time of fax/tel switchover
017
pseudo RBT signal pattern ON time length
018
pseudo RBT signal pattern OFF time length (short)
019
pseudo RBT signal pattern OFF time length (long)
020
pseudo CI signal pattern ON time length
021
pseudo CI signal pattern OFF time length (short)
022
pseudo CI signal pattern OFF time length (long)
023
CNG detection level at time of fax/tel switchover
024
pseudo RBT transmission level at time of fax/tel switchover
025
Answering machine connection function signal detection time
027
preamble detection time length for V21 low-speed flag
051
Hooking detection threshold
053
Setting of DTMF call origination count at remote reception of fax
054
Setting of busy tone output time when handset is used
055
acquisition period of environmental log data
056
display the type of soft counter 1
057
Display the type of soft counter 2
058
Display the type of soft counter 3
059
Display the type of soft counter 4
060
Display the type of soft counter 5
061
Display the type of soft counter 6
074
e-RDS RGW port number
075
Interval of transmission for e-RDS 3rd party
Range of settings
1% to 99%
2 to 99 item
1 to 99 lines
1 to 60 sec
1 to 60 sec
0 to 9999 (10 msec)
0 to 9999 (10 msec)
500 to 3000 (10 msec)
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 7
10 to 20
0 to 20 (120/230V)
4
0 to 999
20 (x 10ms)
0 to 480 (60min)
101 (Fixed)
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999