Floor Protection; Outside Air - Napoleon EPA 1150 Installation And Operating Instructions Manual

Pedestal models
Table of Contents

Advertisement

10
3.4

FLOOR PROTECTION

If the appliance is to be installed on top of a combustible fl oor, it must be placed on an approved non-
combustible hearth pad, that extends 8" beyond the appliance sides and back and 18" to the front. The
reduced clearance from the back of the appliance may result in the appliance pad terminating shorter than 8"
beyond the appliance.
K
J
J
I
3.5

OUTSIDE AIR

IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING
The following are signs that a fresh air kit may be required:
When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
In the winter there is too much condensation on the windows.
Opening a window seems to alleviate the above symptoms.
A ventilation system is installed in the house.
Other devices are present that exhaust house air.
The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.
If possible connect the air intake at the pedestal's back or
bottom to outside air with a 4 inch (100mm) diameter fresh
air kit available at your authorized dealer / distributor.
Follow detailed instructions under "Mobile Home Outside Air".
W415-0763 / A / 11.03.10
FRONT (I)
CANADA
USA
NOTE: If a section of horizontal chimney connector is used, fl oor protection is
required under the chimney connector and 2" beyond each side.
!
APPLIANCE COULD BE DRAWN INTO THE ROOM.
MINIMUM FLOOR PROTECTION
SIDES (J)
18"
8"
16"
8"
WARNING
A (in.)
B (in.)
1100
8 5/8"
9 3/4"
1400
11 1/8"
9 3/4"
1900
14 7/8"
9 3/4"
BACK (K)
8"
8"