1. Lubricate the castor wheel bearings and motion control
lever pivot until grease begins to ooze out of the
bearings (Fig. 70).
m–3289
Figure 70
2. Grease the fittings on drive shaft and universal joints
(Fig. 71).
Figure 71
1. PTO Driveshaft
3. Grease the fitting on the PTO idler pulley
m–5298
Figure 72
1. PTO Idler and pulley
m–5283
m–3203
2. Universal Joint
41
4. Grease the fittings on push arms (Fig. 73).
Figure 73
1. Push arm grease fitting
5. Grease the fittings on the carrier frame castor hubs and
castor wheels (Fig. 74).
Figure 74
1. Carrier Frame Castor Hub
Grease Fitting
Servicing the Gearbox Fluid
Change fluid:
• After initial 100 operating hours.
Note: Fluid will not have to be changed again after initial
100 hour fluid change.
Fluid Type: Automatic Transmission Fluid
®
(Dexron
III or equivalent)
Important
Do not mix fluids. Use only Automatic
Transmission Fluid.
Gearbox Capacity: 5–1/2 oz each box
Check fluid: After every 100 operating hours.
1
m–4871
1
2
m–4846
2. Castor Wheel Grease
Fitting